Predictors of physical capacity 6 months after implantation of a full magnetically levitated left ventricular assist device: an analysis from the ELEVATE registry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F20%3A00079916" target="_blank" >RIV/00023001:_____/20:00079916 - isvavai.cz</a>
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S1071916419306505?token=8E10DF735509623C0D48FE1F4F41F4E1C19BBB5FCCFF2E299B82D91D26FBD2F8423D8DB6BED6FC999FD71F92862CF3EE" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S1071916419306505?token=8E10DF735509623C0D48FE1F4F41F4E1C19BBB5FCCFF2E299B82D91D26FBD2F8423D8DB6BED6FC999FD71F92862CF3EE</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cardfail.2020.04.004" target="_blank" >10.1016/j.cardfail.2020.04.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Predictors of physical capacity 6 months after implantation of a full magnetically levitated left ventricular assist device: an analysis from the ELEVATE registry
Popis výsledku v původním jazyce
Background: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. Methods and Results: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 +/- 10 vs 52 +/- 12 years; P <.001), more often New York Heart Association functional class IV (63% vs 42%; P =.03), and more often had type 2 diabetes (43% vs 17%; P <.001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P <.002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking < 300 m (both P <.01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). Conclusions: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.
Název v anglickém jazyce
Predictors of physical capacity 6 months after implantation of a full magnetically levitated left ventricular assist device: an analysis from the ELEVATE registry
Popis výsledku anglicky
Background: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. Methods and Results: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 +/- 10 vs 52 +/- 12 years; P <.001), more often New York Heart Association functional class IV (63% vs 42%; P =.03), and more often had type 2 diabetes (43% vs 17%; P <.001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P <.002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking < 300 m (both P <.01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). Conclusions: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiac failure
ISSN
1071-9164
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
580-587
Kód UT WoS článku
000551280100009
EID výsledku v databázi Scopus
2-s2.0-85086370282