Clinical impact and 'natural' course of uncorrected tricuspid regurgitation after implantation of a left ventricular assist device: An analysis of the European Registry for Patients with Mechanical Circulatory Support (EUROMACS)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00080763" target="_blank" >RIV/00023001:_____/21:00080763 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/ejcts/article/59/1/207/5920578" target="_blank" >https://academic.oup.com/ejcts/article/59/1/207/5920578</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ejcts/ezaa294" target="_blank" >10.1093/ejcts/ezaa294</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Clinical impact and 'natural' course of uncorrected tricuspid regurgitation after implantation of a left ventricular assist device: An analysis of the European Registry for Patients with Mechanical Circulatory Support (EUROMACS)
Popis výsledku v původním jazyce
Objectives: Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation. Methods: The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. Results: A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06-1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. Conclusions: Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progressively without intervention after an LVAD implant. Therefore, these data suggest that patient selection for concomitant tricuspid valve surgery should not be based solely on TR grade. © 2020 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.
Název v anglickém jazyce
Clinical impact and 'natural' course of uncorrected tricuspid regurgitation after implantation of a left ventricular assist device: An analysis of the European Registry for Patients with Mechanical Circulatory Support (EUROMACS)
Popis výsledku anglicky
Objectives: Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation. Methods: The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. Results: A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06-1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. Conclusions: Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progressively without intervention after an LVAD implant. Therefore, these data suggest that patient selection for concomitant tricuspid valve surgery should not be based solely on TR grade. © 2020 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European journal of cardio-thoracic surgery
ISSN
1010-7940
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
207-216
Kód UT WoS článku
000609900500025
EID výsledku v databázi Scopus
2-s2.0-85099427443