A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00080800" target="_blank" >RIV/00023001:_____/21:00080800 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/21:00074697 RIV/00023884:_____/21:00009069
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S2405500X20311907?token=F3476426BC5F554AD40D241979293135DC771660BEAC0AE80FE29221909D6475357F7A39E09A866DE1E3B6D5FB733F15" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S2405500X20311907?token=F3476426BC5F554AD40D241979293135DC771660BEAC0AE80FE29221909D6475357F7A39E09A866DE1E3B6D5FB733F15</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacep.2020.11.009" target="_blank" >10.1016/j.jacep.2020.11.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation
Popis výsledku v původním jazyce
Objectives: DIAMOND-AF (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation) was a prospective, multicenter, noninferiority, randomized trial that compared the safety and effectiveness of the DTA system versus those of a force-sensing RF ablation system (control) for the treatment of patients with drug-refractory, recurrent, symptomatic paroxysmal atrial fibrillation (AF). Background: Irrigated radiofrequency (RF) ablation catheters lose tissue temperature acuity, which is vital in assessing lesion formation. DiamondTemp Ablation (DTA) was designed to re-establish accurate tissue temperature measurements during ablation. Methods: A total of 482 patients with paroxysmal AF were randomized (239 DTA, 243 control) to undergo pulmonary vein isolation and were followed up at 23 sites. Patients were screened for disease progression, cardiac characteristics, and prior interventions. Primary endpoints were effectiveness (freedom from atrial arrhythmia recurrence) and safety (composite of procedure- and device-related serious adverse events). Results: The primary safety event rate was 3.3% in the DTA group versus 6.6% in the control group (p < 0.001 vs. 6.5% noninferiority margin). Primary effectiveness was met in 79.1% of DTA subjects and 75.7% of control subjects (p < 0.001 vs. -12.5% noninferiority margin). Secondary endpoint analysis found that off-drug effectiveness favored DTA compared with the control (142 [59.4%] vs. 120 [49.4%], respectively; p = 0.03). Total RF time and individual RF ablation duration were significantly shorter with less saline infused through the DTA catheter (p < 0.001). Both arms saw clinically meaningful improvements in quality of life at 12 months. Conclusions: Safety and efficacy of the DTA system proved noninferior to force-sensing RF ablation in a paroxysmal AF population. Efficiencies were observed using DTA with shorter total RF times, individual RF ablation durations, and less saline infusion. (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation; NCT03334630) © 2021 The Authors
Název v anglickém jazyce
A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation
Popis výsledku anglicky
Objectives: DIAMOND-AF (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation) was a prospective, multicenter, noninferiority, randomized trial that compared the safety and effectiveness of the DTA system versus those of a force-sensing RF ablation system (control) for the treatment of patients with drug-refractory, recurrent, symptomatic paroxysmal atrial fibrillation (AF). Background: Irrigated radiofrequency (RF) ablation catheters lose tissue temperature acuity, which is vital in assessing lesion formation. DiamondTemp Ablation (DTA) was designed to re-establish accurate tissue temperature measurements during ablation. Methods: A total of 482 patients with paroxysmal AF were randomized (239 DTA, 243 control) to undergo pulmonary vein isolation and were followed up at 23 sites. Patients were screened for disease progression, cardiac characteristics, and prior interventions. Primary endpoints were effectiveness (freedom from atrial arrhythmia recurrence) and safety (composite of procedure- and device-related serious adverse events). Results: The primary safety event rate was 3.3% in the DTA group versus 6.6% in the control group (p < 0.001 vs. 6.5% noninferiority margin). Primary effectiveness was met in 79.1% of DTA subjects and 75.7% of control subjects (p < 0.001 vs. -12.5% noninferiority margin). Secondary endpoint analysis found that off-drug effectiveness favored DTA compared with the control (142 [59.4%] vs. 120 [49.4%], respectively; p = 0.03). Total RF time and individual RF ablation duration were significantly shorter with less saline infused through the DTA catheter (p < 0.001). Both arms saw clinically meaningful improvements in quality of life at 12 months. Conclusions: Safety and efficacy of the DTA system proved noninferior to force-sensing RF ablation in a paroxysmal AF population. Efficiencies were observed using DTA with shorter total RF times, individual RF ablation durations, and less saline infusion. (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation; NCT03334630) © 2021 The Authors
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JACC Clinical Electrophysiology
ISSN
2405-500X
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
352-363
Kód UT WoS článku
000629482200008
EID výsledku v databázi Scopus
2-s2.0-85100647893