A broad tuneable birdcage coil for mouse H-1/F-19 MR applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00081474" target="_blank" >RIV/00023001:_____/21:00081474 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/21:10436587
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S1090780721001129?token=AFD0F21947EAB69E48461A9505F0397E3AA4DBA6E4D04D7988E06A3DD72A7CAE169052B0219D0B9CCA92EA5CEF02FAC2&originRegion=eu-west-1&originCreation=20210915135900" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S1090780721001129?token=AFD0F21947EAB69E48461A9505F0397E3AA4DBA6E4D04D7988E06A3DD72A7CAE169052B0219D0B9CCA92EA5CEF02FAC2&originRegion=eu-west-1&originCreation=20210915135900</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmr.2021.107023" target="_blank" >10.1016/j.jmr.2021.107023</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A broad tuneable birdcage coil for mouse H-1/F-19 MR applications
Popis výsledku v původním jazyce
In this paper, we present the design and implementation of a H-1/F-19 volume coil for mouse body magnetic resonance (MR) imaging and spectroscopy using a high magnetic field (4.7 T). By changing the geometry of the coil rungs to include both nuclei for MR experiments, this innovative coil can be tuned over an extremely wide range of frequency. The coil, 45 mm in diameter and 55 mm in length, consists of a 12-rung birdcage-like structure. Using two types of tuning, the coil can generate a sufficiently homogeneous B1 electromagnetic field within a working volume optimized for laboratory mouse. The first tuning involves changing the resonance frequency over a large frequency range. The electrical capacitance between the wires can be adjusted to reflect changes in the length of the coil. The second tuning comprises a habitual tuning transformer for precise detection in a narrow band. In contrast to widely used multinuclear coils, the coil presented here features only one resonance peak and can be manipulated according to the Larmor frequencies given for H-1 and F-19. The coil was successfully tested using full-wave simulations of magnetic and electric field distributions under in vivo MR conditions. (C) 2021 Elsevier Inc. All rights reserved.
Název v anglickém jazyce
A broad tuneable birdcage coil for mouse H-1/F-19 MR applications
Popis výsledku anglicky
In this paper, we present the design and implementation of a H-1/F-19 volume coil for mouse body magnetic resonance (MR) imaging and spectroscopy using a high magnetic field (4.7 T). By changing the geometry of the coil rungs to include both nuclei for MR experiments, this innovative coil can be tuned over an extremely wide range of frequency. The coil, 45 mm in diameter and 55 mm in length, consists of a 12-rung birdcage-like structure. Using two types of tuning, the coil can generate a sufficiently homogeneous B1 electromagnetic field within a working volume optimized for laboratory mouse. The first tuning involves changing the resonance frequency over a large frequency range. The electrical capacitance between the wires can be adjusted to reflect changes in the length of the coil. The second tuning comprises a habitual tuning transformer for precise detection in a narrow band. In contrast to widely used multinuclear coils, the coil presented here features only one resonance peak and can be manipulated according to the Larmor frequencies given for H-1 and F-19. The coil was successfully tested using full-wave simulations of magnetic and electric field distributions under in vivo MR conditions. (C) 2021 Elsevier Inc. All rights reserved.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-03207S" target="_blank" >GA19-03207S: Bimetalické a trimetalické fluorescentní nanoklastry: syntéza, fyzikálně-chemické vlastnosti, a aplikace pro zobrazování biologických systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of magnetic resonance
ISSN
1090-7807
e-ISSN
—
Svazek periodika
329
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
"Art. No. 107023"
Kód UT WoS článku
000677682100007
EID výsledku v databázi Scopus
2-s2.0-85107919882