Acute hemodynamic effect of a novel dual-vein, multisite biventricular pacing configuration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F23%3A00084420" target="_blank" >RIV/00023001:_____/23:00084420 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/23:00371273 RIV/00216208:11110/23:10473240
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2405500X23005200?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2405500X23005200?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacep.2023.07.007" target="_blank" >10.1016/j.jacep.2023.07.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Acute hemodynamic effect of a novel dual-vein, multisite biventricular pacing configuration
Popis výsledku v původním jazyce
Background: Biventricular pacing (BVP) from multiple left ventricular (LV) sites could enhance the efficacy of cardiac resynchronization therapy (CRT) by engaging a greater myocardial mass. Objectives: The goal of this study was to evaluate the acute hemodynamic effect of various multisite pacing (MSP) configurations against conventional BVP. Methods: Twenty patients with nonischemic dilated cardiomyopathy and left bundle branch block (mean age: 59 ± 14 years; LV ejection fraction: 27% ± 6%; native QRS: 171 ± 16 milliseconds) were investigated during a routine CRT implant procedure. In addition to conventional right atrial and right ventricular leads, 2 quadripolar leads were placed in the distant coronary venous branches. LV hemodynamics was evaluated by using a micromanometer-tipped catheter during atrioventricular BVP with 4 LV lead configurations: single-lead conventional BVP; single-lead multipoint pacing; triventricular pacing from distal dipoles of 2 LV leads; and maximum MSP (MSP-Max) from 4 dipoles of 2 LV leads. Results: Compared with right atrial pacing, any BVP configuration produced a significant increase in the maximal LV diastolic pressure rise (LVdP/dTMax) (a median relative increase of 28% [IQR: 8%-45%], 25% [IQR: 18%-46%], 36% [IQR: 18%-54%], and 38% [IQR: 28%-58%], respectively; all, P < 0.001). MSP-Max but no other multisite BVP generated a significant increase of the maximal LVdP/dTMax than conventional BVP (P = 0.041). Increased LVdP/dTMax during MSP-Max was associated with greater LV diameter and lower LV ejection fraction, independently of the QRS width. Conclusions: The study shows the hemodynamic advantage of a novel dual-vein MSP-Max configuration that could be useful for CRT in patients with advanced LV remodeling. © 2023 American College of Cardiology Foundation
Název v anglickém jazyce
Acute hemodynamic effect of a novel dual-vein, multisite biventricular pacing configuration
Popis výsledku anglicky
Background: Biventricular pacing (BVP) from multiple left ventricular (LV) sites could enhance the efficacy of cardiac resynchronization therapy (CRT) by engaging a greater myocardial mass. Objectives: The goal of this study was to evaluate the acute hemodynamic effect of various multisite pacing (MSP) configurations against conventional BVP. Methods: Twenty patients with nonischemic dilated cardiomyopathy and left bundle branch block (mean age: 59 ± 14 years; LV ejection fraction: 27% ± 6%; native QRS: 171 ± 16 milliseconds) were investigated during a routine CRT implant procedure. In addition to conventional right atrial and right ventricular leads, 2 quadripolar leads were placed in the distant coronary venous branches. LV hemodynamics was evaluated by using a micromanometer-tipped catheter during atrioventricular BVP with 4 LV lead configurations: single-lead conventional BVP; single-lead multipoint pacing; triventricular pacing from distal dipoles of 2 LV leads; and maximum MSP (MSP-Max) from 4 dipoles of 2 LV leads. Results: Compared with right atrial pacing, any BVP configuration produced a significant increase in the maximal LV diastolic pressure rise (LVdP/dTMax) (a median relative increase of 28% [IQR: 8%-45%], 25% [IQR: 18%-46%], 36% [IQR: 18%-54%], and 38% [IQR: 28%-58%], respectively; all, P < 0.001). MSP-Max but no other multisite BVP generated a significant increase of the maximal LVdP/dTMax than conventional BVP (P = 0.041). Increased LVdP/dTMax during MSP-Max was associated with greater LV diameter and lower LV ejection fraction, independently of the QRS width. Conclusions: The study shows the hemodynamic advantage of a novel dual-vein MSP-Max configuration that could be useful for CRT in patients with advanced LV remodeling. © 2023 American College of Cardiology Foundation
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV18-02-00080" target="_blank" >NV18-02-00080: Elektrická aktivace myokardu levé komory při aplikaci modifikovaného epikardiálního triventrikulárního systému pro srdeční resynchronizační léčbu srdečního selhání</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JACC Clinical Electrophysiology
ISSN
2405-500X
e-ISSN
2405-5018
Svazek periodika
9
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
2329-2338
Kód UT WoS článku
001129919900001
EID výsledku v databázi Scopus
2-s2.0-85173188164