Development and evaluation of a secondary reference panel for BCR-ABL1 quantification on the International Scale
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023736%3A_____%2F16%3A00011550" target="_blank" >RIV/00023736:_____/16:00011550 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00092596 RIV/65269705:_____/16:00066093
Výsledek na webu
<a href="http://dx.doi.org/10.1038/leu.2016.90" target="_blank" >http://dx.doi.org/10.1038/leu.2016.90</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/leu.2016.90" target="_blank" >10.1038/leu.2016.90</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development and evaluation of a secondary reference panel for BCR-ABL1 quantification on the International Scale
Popis výsledku v původním jazyce
Molecular monitoring of chronic myeloid leukemia patients using robust BCR-ABL1 tests standardized to the International Scale (IS) is key to proper disease management, especially when treatment cessation is considered. Most laboratories currently use a time-consuming sample exchange process with reference laboratories for IS calibration. A World Health Organization (WHO) BCR-ABL1 reference panel was developed (MR 1 -MR 4), but access to the material is limited. In this study, we describe the development of the first cell-based secondary reference panel that is traceable to and faithfully replicates the WHO panel, with an additional MR 4.5 level. The secondary panel was calibrated to IS using digital PCR with ABL1, BCR and GUSB as reference genes and evaluated by 44 laboratories worldwide.
Název v anglickém jazyce
Development and evaluation of a secondary reference panel for BCR-ABL1 quantification on the International Scale
Popis výsledku anglicky
Molecular monitoring of chronic myeloid leukemia patients using robust BCR-ABL1 tests standardized to the International Scale (IS) is key to proper disease management, especially when treatment cessation is considered. Most laboratories currently use a time-consuming sample exchange process with reference laboratories for IS calibration. A World Health Organization (WHO) BCR-ABL1 reference panel was developed (MR 1 -MR 4), but access to the material is limited. In this study, we describe the development of the first cell-based secondary reference panel that is traceable to and faithfully replicates the WHO panel, with an additional MR 4.5 level. The secondary panel was calibrated to IS using digital PCR with ABL1, BCR and GUSB as reference genes and evaluated by 44 laboratories worldwide.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Leukemia
ISSN
0887-6924
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
1844-1852
Kód UT WoS článku
000383786400021
EID výsledku v databázi Scopus
—