Methods for Removing of Line Noise Artifact from EEG Records with Minimization of Neural Information Loss
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023752%3A_____%2F20%3A43920117" target="_blank" >RIV/00023752:_____/20:43920117 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/20:00336907
Výsledek na webu
<a href="https://link.springer.com/chapter/10.1007%2F978-3-030-31635-8_22" target="_blank" >https://link.springer.com/chapter/10.1007%2F978-3-030-31635-8_22</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-030-31635-8_22" target="_blank" >10.1007/978-3-030-31635-8_22</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methods for Removing of Line Noise Artifact from EEG Records with Minimization of Neural Information Loss
Popis výsledku v původním jazyce
Line noise is artifact affecting a gamma band of the EEG. Conventional filters are used for removing the line noise artifact, but these filters, also remove physiological activity and could induce spurious oscillations. We tested two alternative methods for removing line noise artifact without removing a physiological activity, specifically Adaptive noise cancellation (ANC) method with Linear regression and modified Independent Component Analysis (ICA). We proposed a new protocol for statistical evaluation of line noise removal effectiveness. The line noise artifact was physically simulated and the protocol for statistical evaluation was verified. The ANC method shows good results according to statistical evaluation. The lowest residuum of simulated line noise artifact corresponds to 0.0005 Hz. Nevertheless, the ANC is very sensitive to the quality of the reference signal, which heavily depends on the reference electrode selection.
Název v anglickém jazyce
Methods for Removing of Line Noise Artifact from EEG Records with Minimization of Neural Information Loss
Popis výsledku anglicky
Line noise is artifact affecting a gamma band of the EEG. Conventional filters are used for removing the line noise artifact, but these filters, also remove physiological activity and could induce spurious oscillations. We tested two alternative methods for removing line noise artifact without removing a physiological activity, specifically Adaptive noise cancellation (ANC) method with Linear regression and modified Independent Component Analysis (ICA). We proposed a new protocol for statistical evaluation of line noise removal effectiveness. The line noise artifact was physically simulated and the protocol for statistical evaluation was verified. The ANC method shows good results according to statistical evaluation. The lowest residuum of simulated line noise artifact corresponds to 0.0005 Hz. Nevertheless, the ANC is very sensitive to the quality of the reference signal, which heavily depends on the reference electrode selection.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019; Coimbra; Portugal; 26 September 2019 through 28 September 2019
ISBN
978-3-030-31634-1
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
9
Strana od-do
184-192
Název nakladatele
Springer Nature
Místo vydání
Switzerland
Místo konání akce
Coimbra, Portugal
Datum konání akce
26. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—