Mu rhythm separation from the mix with alpha rhythm: Principal component analyses and factor topography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023752%3A_____%2F20%3A43920457" target="_blank" >RIV/00023752:_____/20:43920457 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/20:43920412
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0165027020303150?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0165027020303150?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jneumeth.2020.108892" target="_blank" >10.1016/j.jneumeth.2020.108892</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mu rhythm separation from the mix with alpha rhythm: Principal component analyses and factor topography
Popis výsledku v původním jazyce
Background: EEG mu rhythm suppression is assessed in experiments on the execution, observation and imagination of movements. It is utilised for studying of actions, language, empathy in healthy individuals and preservation of sensorimotor system functions in patients with schizophrenia and autism spectrum disorders. While EEG alpha and mu rhythms are recorded in the same frequency range (8−13 Hz), their specification becomes a serious issue. The new method: is based on the spatial and functional characteristics of the mu wave, which are: (1) the mu rhythm is located over the sensorimotor cortex; (2) it desynchronises during movement processing and does not respond on the eyes opening. In EEG recordings, we analysed the mu rhythm under conditions with eyes opened and eyes closed (baseline), and during a motor imagery task with eyes closed. EEG recordings were processed by principal component analysis (PCA). Results: The analysis of EEG data with the proposed approach revealed the maximum spectral power of mu rhythm localised in the sensorimotor areas. During motor imagery, mu rhythm was suppressed more in frontal and central sites than in occipital sites, whereas alpha rhythm was suppressed more in parietal and occipital sites. Mu rhythm desynchronization in sensorimotor sites during motor imagery was greater than alpha rhythm desynchronization. The proposed method enabled EEG mu rhythm separation from its mix with alpha rhythm. Conclusions: EEG mu rhythm separation with the proposed method satisfies its classical definition.
Název v anglickém jazyce
Mu rhythm separation from the mix with alpha rhythm: Principal component analyses and factor topography
Popis výsledku anglicky
Background: EEG mu rhythm suppression is assessed in experiments on the execution, observation and imagination of movements. It is utilised for studying of actions, language, empathy in healthy individuals and preservation of sensorimotor system functions in patients with schizophrenia and autism spectrum disorders. While EEG alpha and mu rhythms are recorded in the same frequency range (8−13 Hz), their specification becomes a serious issue. The new method: is based on the spatial and functional characteristics of the mu wave, which are: (1) the mu rhythm is located over the sensorimotor cortex; (2) it desynchronises during movement processing and does not respond on the eyes opening. In EEG recordings, we analysed the mu rhythm under conditions with eyes opened and eyes closed (baseline), and during a motor imagery task with eyes closed. EEG recordings were processed by principal component analysis (PCA). Results: The analysis of EEG data with the proposed approach revealed the maximum spectral power of mu rhythm localised in the sensorimotor areas. During motor imagery, mu rhythm was suppressed more in frontal and central sites than in occipital sites, whereas alpha rhythm was suppressed more in parietal and occipital sites. Mu rhythm desynchronization in sensorimotor sites during motor imagery was greater than alpha rhythm desynchronization. The proposed method enabled EEG mu rhythm separation from its mix with alpha rhythm. Conclusions: EEG mu rhythm separation with the proposed method satisfies its classical definition.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Neuroscience Methods
ISSN
0165-0270
e-ISSN
—
Svazek periodika
346
Číslo periodika v rámci svazku
"Article Number: 108892"
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
000580629300003
EID výsledku v databázi Scopus
2-s2.0-85089506012