Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F15%3A%230007161" target="_blank" >RIV/00023884:_____/15:#0007161 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation
Popis výsledku v původním jazyce
We evaluated the correlation between pulmonary venous (PV) anatomy and acute and long-term success of PV isolation (PVI) with two balloon-based ablation catheter techniques. One hundred consecutive patients were analyzed in two equal groups treated with either the second-generation cryoballoon (CRYO) catheter or the visually guided laser ablation (VGLA) catheter. All patients underwent multi-detector computed tomography (CT) imaging. The primary and secondary efficacy endpoints were the procedural achievement of proven electrical isolation of all veins and freedom from atrial fibrillation (AF) within a 1-year follow-up period, respectively. Variant PV anatomy was observed in 32 % of patients in the CRYO group and in 40 % of patients in the VGLA group. All PVs were targeted with either the CRYO catheter (n = 199) or the VGLA catheter (n = 206). One hundred ninety-three of 199 PVs (97 %) were successfully isolated in the CRYO group and 194 of 206 PVs (94 %) in the VGLA group (p = 0.83). Over a 12-month follow-up, AF recurrence was documented in 11/45 (24 %) and 7/43 (16 %) patients in the CRYO and the VGLA groups, respectively (p = 0.21). In the CRYO group, a larger left inferior PV size was associated with worse long-term outcome (p = 0.001). In the VGLA group, a larger left superior PV size (p = 0.003) and more oval right inferior PV were associated with worse acute success (p = 0.038). There was no absolute cutoff between PV anatomy and clinical success. The variability of PV anatomy did not significantly compromise acute success of PVI or patient outcomes.
Název v anglickém jazyce
Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation
Popis výsledku anglicky
We evaluated the correlation between pulmonary venous (PV) anatomy and acute and long-term success of PV isolation (PVI) with two balloon-based ablation catheter techniques. One hundred consecutive patients were analyzed in two equal groups treated with either the second-generation cryoballoon (CRYO) catheter or the visually guided laser ablation (VGLA) catheter. All patients underwent multi-detector computed tomography (CT) imaging. The primary and secondary efficacy endpoints were the procedural achievement of proven electrical isolation of all veins and freedom from atrial fibrillation (AF) within a 1-year follow-up period, respectively. Variant PV anatomy was observed in 32 % of patients in the CRYO group and in 40 % of patients in the VGLA group. All PVs were targeted with either the CRYO catheter (n = 199) or the VGLA catheter (n = 206). One hundred ninety-three of 199 PVs (97 %) were successfully isolated in the CRYO group and 194 of 206 PVs (94 %) in the VGLA group (p = 0.83). Over a 12-month follow-up, AF recurrence was documented in 11/45 (24 %) and 7/43 (16 %) patients in the CRYO and the VGLA groups, respectively (p = 0.21). In the CRYO group, a larger left inferior PV size was associated with worse long-term outcome (p = 0.001). In the VGLA group, a larger left superior PV size (p = 0.003) and more oval right inferior PV were associated with worse acute success (p = 0.038). There was no absolute cutoff between PV anatomy and clinical success. The variability of PV anatomy did not significantly compromise acute success of PVI or patient outcomes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Interventional Cardiac Electrophysiology
ISSN
1383-875X
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
265-271
Kód UT WoS článku
000364933300008
EID výsledku v databázi Scopus
2-s2.0-84947129005