Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F18%3A00007293" target="_blank" >RIV/00023884:_____/18:00007293 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/18:00326380 RIV/00064203:_____/18:10375330
Výsledek na webu
<a href="http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7" target="_blank" >http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7" target="_blank" >10.18869/acadpub.ijrr.16.1.7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Popis výsledku v původním jazyce
Background: To determine the basic physical and dosimetric properes of a new synthec single-crystal diamond detector and its applicaon for relave small field dosimetry. Materials and Methods: The pre-irradiaon dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector response were evaluated. Output factors on Leksell Gamma Knife Perfexion and on CyberKnife were measured to assess detector feasibility in small radiaon field dosimetry. For all measurements, the detector was connected to Unidos electrometer set to 0 voltage. Results: Relave output factors measured on Leksell Gamma Knife Perfexion for 4 mm and 8 mm collimators were in agreement with Monte Carlo reference values from the manufacturer, with deviaons of 0.3% and 2.1%, respecvely. For CyberKnife and fixed circular collimators, the difference in output factor values did not exceed 2% from vendor-supplied values, even for the smallest radiaon field with a diameter of 5 mm. Conclusion: Our results indicate that the MicroDiamond detector is a promising tool for relave small field dosimetry. For output factor measurements on Leksell Gamma Knife Perfexion and CyberKnife, the detector can be used with minimal response correcons applied (correcon factors not larger than 2%).
Název v anglickém jazyce
Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Popis výsledku anglicky
Background: To determine the basic physical and dosimetric properes of a new synthec single-crystal diamond detector and its applicaon for relave small field dosimetry. Materials and Methods: The pre-irradiaon dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector response were evaluated. Output factors on Leksell Gamma Knife Perfexion and on CyberKnife were measured to assess detector feasibility in small radiaon field dosimetry. For all measurements, the detector was connected to Unidos electrometer set to 0 voltage. Results: Relave output factors measured on Leksell Gamma Knife Perfexion for 4 mm and 8 mm collimators were in agreement with Monte Carlo reference values from the manufacturer, with deviaons of 0.3% and 2.1%, respecvely. For CyberKnife and fixed circular collimators, the difference in output factor values did not exceed 2% from vendor-supplied values, even for the smallest radiaon field with a diameter of 5 mm. Conclusion: Our results indicate that the MicroDiamond detector is a promising tool for relave small field dosimetry. For output factor measurements on Leksell Gamma Knife Perfexion and CyberKnife, the detector can be used with minimal response correcons applied (correcon factors not larger than 2%).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Radiation Research
ISSN
2322-3243
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
IR - Íránská islámská republika
Počet stran výsledku
10
Strana od-do
7-16
Kód UT WoS článku
000427559900002
EID výsledku v databázi Scopus
2-s2.0-85043272002