A modular Geant4 model of Leksell Gamma Knife Perfexion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F14%3A00224873" target="_blank" >RIV/68407700:21340/14:00224873 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/0031-9155/59/24/7609" target="_blank" >http://dx.doi.org/10.1088/0031-9155/59/24/7609</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0031-9155/59/24/7609" target="_blank" >10.1088/0031-9155/59/24/7609</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A modular Geant4 model of Leksell Gamma Knife Perfexion
Popis výsledku v původním jazyce
This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase space files were created, containing particles that are entering the inner machine cavity after being transported through the collimation system. All 14 output factors of the machine and effective output factors for both the 4 mm (0.830 ? 0.009) and 8 mm (0.921 ? 0.004) collimators were calculated. Dose profiles along the main axes are also included for each collimator size. All results are compared to the values obtained from the treatment planning system, from experiments, and from other Monte Carlo models.
Název v anglickém jazyce
A modular Geant4 model of Leksell Gamma Knife Perfexion
Popis výsledku anglicky
This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase space files were created, containing particles that are entering the inner machine cavity after being transported through the collimation system. All 14 output factors of the machine and effective output factors for both the 4 mm (0.830 ? 0.009) and 8 mm (0.921 ? 0.004) collimators were calculated. Dose profiles along the main axes are also included for each collimator size. All results are compared to the values obtained from the treatment planning system, from experiments, and from other Monte Carlo models.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physics in Medicine and Biology
ISSN
0031-9155
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
24
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
15
Strana od-do
7609-7623
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—