Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F23%3A00009700" target="_blank" >RIV/00023884:_____/23:00009700 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/europace/article/25/11/euad308/7416771?login=true" target="_blank" >https://academic.oup.com/europace/article/25/11/euad308/7416771?login=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euad308" target="_blank" >10.1093/europace/euad308</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'
Popis výsledku v původním jazyce
Aims Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility.Methods and results In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF.Conclusion Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
Název v anglickém jazyce
Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'
Popis výsledku anglicky
Aims Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility.Methods and results In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF.Conclusion Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
001104478100002
EID výsledku v databázi Scopus
2-s2.0-85176893778