Pulmonary valve neo-reconstruction using the Ozaki technique in an adapted Ross procedure: case report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010218" target="_blank" >RIV/00023884:_____/25:00010218 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/25:10500073
Výsledek na webu
<a href="https://academic.oup.com/ehjcr/article/9/7/ytaf291/8168869" target="_blank" >https://academic.oup.com/ehjcr/article/9/7/ytaf291/8168869</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ehjcr/ytaf291" target="_blank" >10.1093/ehjcr/ytaf291</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulmonary valve neo-reconstruction using the Ozaki technique in an adapted Ross procedure: case report
Popis výsledku v původním jazyce
Aortic valve damage is the most common valvular heart disease in developed countries. The Ross procedure is an alternative to the aortic valve replacement with a prosthesis, providing a longer survival without reoperation and without the need for anticoagulation therapy. The unavailability of homografts for the pulmonary valve replacement is one of the limiting factors for a more common utilization of this therapeutic method.Case summary This case report presents a 35-year-old Caucasian male with a bicuspid aortic valve and severe aortic regurgitation. The patient underwent the Ross procedure with the stabilization of the aortic ring and sinotubular junction. A tubular prosthesis was created from the bovine pericardium, into which three neo-cusp valves were fashioned from autologous pericardium. The new pulmonary conduit was sutured distally to the distal pulmonary trunk and proximally to the right ventricular outflow tract. Four months post-operatively, the follow-up echocardiographic examination documented that the valve in the aortic position had no regurgitation, a maximum velocity of 1.25 m/s, and a peak gradient of 6.25 mmHg. The valve in the pulmonary position showed a trace regurgitation and mean pressure gradient of 13 mmHg.Discussion The combination of the modified Ross procedure with neo-cuspidalization according to Ozaki for a new pulmonary valve thus offers hope for an extended survival without reoperation in paediatric and non-elderly adult patients with an aortic valve dysfunction. This technique is additionally applicable by cardiac surgery centres without access to pulmonary homografts.
Název v anglickém jazyce
Pulmonary valve neo-reconstruction using the Ozaki technique in an adapted Ross procedure: case report
Popis výsledku anglicky
Aortic valve damage is the most common valvular heart disease in developed countries. The Ross procedure is an alternative to the aortic valve replacement with a prosthesis, providing a longer survival without reoperation and without the need for anticoagulation therapy. The unavailability of homografts for the pulmonary valve replacement is one of the limiting factors for a more common utilization of this therapeutic method.Case summary This case report presents a 35-year-old Caucasian male with a bicuspid aortic valve and severe aortic regurgitation. The patient underwent the Ross procedure with the stabilization of the aortic ring and sinotubular junction. A tubular prosthesis was created from the bovine pericardium, into which three neo-cusp valves were fashioned from autologous pericardium. The new pulmonary conduit was sutured distally to the distal pulmonary trunk and proximally to the right ventricular outflow tract. Four months post-operatively, the follow-up echocardiographic examination documented that the valve in the aortic position had no regurgitation, a maximum velocity of 1.25 m/s, and a peak gradient of 6.25 mmHg. The valve in the pulmonary position showed a trace regurgitation and mean pressure gradient of 13 mmHg.Discussion The combination of the modified Ross procedure with neo-cuspidalization according to Ozaki for a new pulmonary valve thus offers hope for an extended survival without reoperation in paediatric and non-elderly adult patients with an aortic valve dysfunction. This technique is additionally applicable by cardiac surgery centres without access to pulmonary homografts.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Heart Journal-Case Reports
ISSN
2514-2119
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
001523411300001
EID výsledku v databázi Scopus
2-s2.0-105010074283