Comparison of the Effect of Two Long-Term Commercial Extenders on the Quality of Boar Insemination Doses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027014%3A_____%2F23%3A10005766" target="_blank" >RIV/00027014:_____/23:10005766 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.respigbreed.cz/2023/2/2.pdf" target="_blank" >https://www.respigbreed.cz/2023/2/2.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of the Effect of Two Long-Term Commercial Extenders on the Quality of Boar Insemination Doses
Popis výsledku v původním jazyce
The objective of this study was to compare the effect of two long-term commercial extenders on the quality of boar insemination doses using SCA and flow cytometry. Eleven ejaculates from 7 healthy and fertile AI boars were used for this study. Fresh boar semen was diluted in long-term commercial extenders Androstar plus and Novistar in a semen-dilution ratio of 1+2. Insemination doses (ID) were stored at a 17o C. Sperm viability, acrosome integrity, mitochondrial function, lipid membrane peroxidation, sperm motility (progressive, non-progressive and immotile) and kinetic characteristics were evaluated in ID after 0h, 72h and 168h storage time. According to the results, no significant differences were found in the monitored quality parameters of boar ID between the extenders during the storage time (p>0.05). In conclusion, statistically significant differences between tested long-term extenders were not found in the monitored boar semen quality parameters during storage time. Androstar plus and Novistar long-term extenders maintained the high quality of insemination doses for up to 168 hours of storage.
Název v anglickém jazyce
Comparison of the Effect of Two Long-Term Commercial Extenders on the Quality of Boar Insemination Doses
Popis výsledku anglicky
The objective of this study was to compare the effect of two long-term commercial extenders on the quality of boar insemination doses using SCA and flow cytometry. Eleven ejaculates from 7 healthy and fertile AI boars were used for this study. Fresh boar semen was diluted in long-term commercial extenders Androstar plus and Novistar in a semen-dilution ratio of 1+2. Insemination doses (ID) were stored at a 17o C. Sperm viability, acrosome integrity, mitochondrial function, lipid membrane peroxidation, sperm motility (progressive, non-progressive and immotile) and kinetic characteristics were evaluated in ID after 0h, 72h and 168h storage time. According to the results, no significant differences were found in the monitored quality parameters of boar ID between the extenders during the storage time (p>0.05). In conclusion, statistically significant differences between tested long-term extenders were not found in the monitored boar semen quality parameters during storage time. Androstar plus and Novistar long-term extenders maintained the high quality of insemination doses for up to 168 hours of storage.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
40203 - Husbandry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Research in Pig Breeding
ISSN
1802-7547
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
6-11
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—