Liner chamber vacuum stability analysis during milking in automatic milking system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027031%3A_____%2F09%3A0R000260" target="_blank" >RIV/00027031:_____/09:0R000260 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Liner chamber vacuum stability analysis during milking in automatic milking system
Popis výsledku v původním jazyce
The vacuum stability measurement was carried-out under both laboratory and operational conditions using robot Lely Astronaut A3 with equally adjusted parameters of milking equipment. Milk flow-rate was evaluated from the video record display of controlling unit. The measured values have proved that vacuum average value decreasing within whole pulsation time is lower under laboratory conditions as compared with milking while till the flow-rate of 0,5 l/min the difference is 2 kPa. The significant difference occurs from a quarter flow-rate of 0,7 l/min where the average vacuum in liner chamber is lower by 4 kPa during milking within whole pulsation time. At the quarter flow-rate over 2,5 l/min that difference was 1,5 kPa. These differences are caused inparticular by the fact that during milking the teat cup is suspended unsupported from the udder and with the dairy cow motion the non-defined air suction around the teats occurs as well as the hydraulic strokes in the long milk hose.
Název v anglickém jazyce
Liner chamber vacuum stability analysis during milking in automatic milking system
Popis výsledku anglicky
The vacuum stability measurement was carried-out under both laboratory and operational conditions using robot Lely Astronaut A3 with equally adjusted parameters of milking equipment. Milk flow-rate was evaluated from the video record display of controlling unit. The measured values have proved that vacuum average value decreasing within whole pulsation time is lower under laboratory conditions as compared with milking while till the flow-rate of 0,5 l/min the difference is 2 kPa. The significant difference occurs from a quarter flow-rate of 0,7 l/min where the average vacuum in liner chamber is lower by 4 kPa during milking within whole pulsation time. At the quarter flow-rate over 2,5 l/min that difference was 1,5 kPa. These differences are caused inparticular by the fact that during milking the teat cup is suspended unsupported from the udder and with the dairy cow motion the non-defined air suction around the teats occurs as well as the hydraulic strokes in the long milk hose.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sixth International Scientific and Practical Conference ?Ecology and agricultural machinery?
ISBN
978-5-88890-058-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Research Institute of Agricultural Engineering and Electrification
Místo vydání
Saint-Petersburg-Pavlovsk
Místo konání akce
Saint-Petersburg
Datum konání akce
13. 5. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—