Analýza kolísání podtlaku v dojicí jednotce
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027031%3A_____%2F05%3A8P012159" target="_blank" >RIV/00027031:_____/05:8P012159 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of vacuum fluctuation in milking units
Popis výsledku v původním jazyce
For the vacuum conditions measurement of the clusters the vacuum sensors, placed on 4 points of this clusters were used. Evaluated was the vacuum course in the liner chamber and in the claw in total pulse time in maximum and minimum phase by ISO 6690. The measurement was carried out under laboratory conditions and measured values were recorded. Evaluated were 5 different serial produced clusters with the claw volume of 150, 200, 300, 420, 450 and 500 cm3. By the flow- rate of 5 l.min-1 the vacuum decrease in the liner chamber of the clusters was 1.4 x3.3 kPa and in the claw 1.7 x5.3 kPa by the claw type. By the flow rate of 12 l.min-1 vacuum decrease in the liner chamber of the clusters was 4.1 x11.2 kPa and in the claw 3.9 x11.6 kPa. For total pulse time no evidential difference was found in comparison with the vacuum fluctuation evaluated only for maximum phase. The measurements will continue by measuring in the milking parlour during the real milking
Název v anglickém jazyce
Analysis of vacuum fluctuation in milking units
Popis výsledku anglicky
For the vacuum conditions measurement of the clusters the vacuum sensors, placed on 4 points of this clusters were used. Evaluated was the vacuum course in the liner chamber and in the claw in total pulse time in maximum and minimum phase by ISO 6690. The measurement was carried out under laboratory conditions and measured values were recorded. Evaluated were 5 different serial produced clusters with the claw volume of 150, 200, 300, 420, 450 and 500 cm3. By the flow- rate of 5 l.min-1 the vacuum decrease in the liner chamber of the clusters was 1.4 x3.3 kPa and in the claw 1.7 x5.3 kPa by the claw type. By the flow rate of 12 l.min-1 vacuum decrease in the liner chamber of the clusters was 4.1 x11.2 kPa and in the claw 3.9 x11.6 kPa. For total pulse time no evidential difference was found in comparison with the vacuum fluctuation evaluated only for maximum phase. The measurements will continue by measuring in the milking parlour during the real milking
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ICAR Technical Series
ISSN
1563-2504
e-ISSN
—
Svazek periodika
Neuveden
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
307-312
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—