Možnost použití podtlakem řízených pulzátorů u dojicích strojů pro ovce.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F04%3A00002100" target="_blank" >RIV/62156489:43210/04:00002100 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Possible use of vacuum controlled pulsator for sheep milking machines.
Popis výsledku v původním jazyce
Comparison measurements and evaluation of the suitability of three pulsators for sheep milking machines were carried out, i.e. a prototype made by the manufacturer of the milking parlour of the pulsator ratio 50 % (50:50) and two hydraulic pulsators of the Danish manufacturer S.A. Christensen (SAC), models Unipuls-2 of the pulsator ratios 50 % (50:50) and 60 % (60:40). The specified pulsation rate was 2.5 s-1 (150 min-1). It was found that the pulsator prototype made by the milking parlour manufacturerslowly passed air, whereby the vacuum in pulsation chambers did not attain the maximum value. Fig. 2 illustrates the operation of this pulsator. Both SAC pulsators had better parameters and their pulsograms are plotted in Figs 3 and 4. Also the measurements of a liner deformation in dependence on the vacuum in the teatcup pulsation chamber were made based on which the moment of a real liner opening, i.e. at the vacuum of 35 kPa was determined. The results obtained by the experiments carr
Název v anglickém jazyce
Possible use of vacuum controlled pulsator for sheep milking machines.
Popis výsledku anglicky
Comparison measurements and evaluation of the suitability of three pulsators for sheep milking machines were carried out, i.e. a prototype made by the manufacturer of the milking parlour of the pulsator ratio 50 % (50:50) and two hydraulic pulsators of the Danish manufacturer S.A. Christensen (SAC), models Unipuls-2 of the pulsator ratios 50 % (50:50) and 60 % (60:40). The specified pulsation rate was 2.5 s-1 (150 min-1). It was found that the pulsator prototype made by the milking parlour manufacturerslowly passed air, whereby the vacuum in pulsation chambers did not attain the maximum value. Fig. 2 illustrates the operation of this pulsator. Both SAC pulsators had better parameters and their pulsograms are plotted in Figs 3 and 4. Also the measurements of a liner deformation in dependence on the vacuum in the teatcup pulsation chamber were made based on which the moment of a real liner opening, i.e. at the vacuum of 35 kPa was determined. The results obtained by the experiments carr
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Research in agricultural engineering
ISSN
1212-9151
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
23-27
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—