Determination of cysteinyl leukotrienes in exhaled breath condensate: Method combining immunoseparation with LC-ESI-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F11%3A9595" target="_blank" >RIV/00064165:_____/11:9595 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22310/11:43891926 RIV/60461373:22330/11:43891926 RIV/60461373:22330/11:43892670 RIV/60461373:22310/11:43892670 a 2 dalších
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jchromb.2011.06.004" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2011.06.004</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of cysteinyl leukotrienes in exhaled breath condensate: Method combining immunoseparation with LC-ESI-MS/MS
Popis výsledku v původním jazyce
A rapid and precise method for the identification and quantification of cysteinyl leukotrienes (leukotriene C(4), leukotriene D(4) and leukotriene E(4)), essential markers of bronchial asthma, in exhaled breath condensate was developed. The protocol consists of immunoaffinity separation and a detection step, liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized with a high precision (<= 7.7%, determined as RSD), an acceptable accuracy (90.4-93.7%, determined as recovery), a low limitof detection (<= 2 pg/ml EBC) and a low limit of quantification (<= 10 pg/ml EBC). It was compared to other simple, clinically appropriate combinations of pre-treatment methods (solid phase extraction and lyophilization) with LC/MS. Final
Název v anglickém jazyce
Determination of cysteinyl leukotrienes in exhaled breath condensate: Method combining immunoseparation with LC-ESI-MS/MS
Popis výsledku anglicky
A rapid and precise method for the identification and quantification of cysteinyl leukotrienes (leukotriene C(4), leukotriene D(4) and leukotriene E(4)), essential markers of bronchial asthma, in exhaled breath condensate was developed. The protocol consists of immunoaffinity separation and a detection step, liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized with a high precision (<= 7.7%, determined as RSD), an acceptable accuracy (90.4-93.7%, determined as recovery), a low limitof detection (<= 2 pg/ml EBC) and a low limit of quantification (<= 10 pg/ml EBC). It was compared to other simple, clinically appropriate combinations of pre-treatment methods (solid phase extraction and lyophilization) with LC/MS. Final
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography B
ISSN
1570-0232
e-ISSN
—
Svazek periodika
879
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
2220-2228
Kód UT WoS článku
000293722800007
EID výsledku v databázi Scopus
—