Popis výsledku v původním jazyce
Vascular stenosis is often described only by its percentage in both clinical and scientific praxis. Previous studies gave inconclusive results regarding the effect of stenosis eccentricity on its hemodynamic effect. The aim of this experimental study was to investigate and quantify the effect of stenosis severity and eccentricity on the pressure drop. A combination of pressure and flow measurements by Particle Imaging Velocimetry (PIV) method was used. Models of the same stenosis significance but with different levels of eccentricity were studied in vitro by PIV. This study has shown that stenosis asymmetry is associated with more profound pressure drop and flow volume decrease. On the contrary, pressure drop and flow volume decrease were not further significantly influenced by the level of asymmetry. Hemodynamic changes associated with stenosis eccentricity must be taken into account in both clinical and scientific studies.
Název v anglickém jazyce
Vascular Stenosis Asymmetry Influences Considerably Pressure Gradient and Flow Volume
Popis výsledku anglicky
Vascular stenosis is often described only by its percentage in both clinical and scientific praxis. Previous studies gave inconclusive results regarding the effect of stenosis eccentricity on its hemodynamic effect. The aim of this experimental study was to investigate and quantify the effect of stenosis severity and eccentricity on the pressure drop. A combination of pressure and flow measurements by Particle Imaging Velocimetry (PIV) method was used. Models of the same stenosis significance but with different levels of eccentricity were studied in vitro by PIV. This study has shown that stenosis asymmetry is associated with more profound pressure drop and flow volume decrease. On the contrary, pressure drop and flow volume decrease were not further significantly influenced by the level of asymmetry. Hemodynamic changes associated with stenosis eccentricity must be taken into account in both clinical and scientific studies.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FB - Endokrinologie, diabetologie, metabolismus, výživa
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
65
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
63-69
Kód UT WoS článku
000377529800007
EID výsledku v databázi Scopus
2-s2.0-84963799868