The Influence of the Anastomosis Angle on the Hemodynamics in the Distal Anastomosis in the Infrainguinal Bypass: an In Vitro Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F16%3A10329193" target="_blank" >RIV/00064165:_____/16:10329193 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/16:10329193 RIV/68407700:21220/16:00330551
Výsledek na webu
<a href="http://www.biomed.cas.cz/physiolres/pdf/65/65_591.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/65/65_591.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Influence of the Anastomosis Angle on the Hemodynamics in the Distal Anastomosis in the Infrainguinal Bypass: an In Vitro Study
Popis výsledku v původním jazyce
The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25 degrees, 45 degrees, and 60 degrees respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45 degrees and 60 degrees models. In the 25 degrees model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.
Název v anglickém jazyce
The Influence of the Anastomosis Angle on the Hemodynamics in the Distal Anastomosis in the Infrainguinal Bypass: an In Vitro Study
Popis výsledku anglicky
The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25 degrees, 45 degrees, and 60 degrees respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45 degrees and 60 degrees models. In the 25 degrees model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
65
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
591-595
Kód UT WoS článku
000386685600006
EID výsledku v databázi Scopus
2-s2.0-84997427329