The Ratio of Diameters Between the Target Artery and the Bypass Modifies Hemodynamic Parameters Related to Intimal Hyperplasia in the Distal End-to-Side Anastomosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00330549" target="_blank" >RIV/68407700:21220/16:00330549 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/16:10330315
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Ratio of Diameters Between the Target Artery and the Bypass Modifies Hemodynamic Parameters Related to Intimal Hyperplasia in the Distal End-to-Side Anastomosis
Popis výsledku v původním jazyce
Hemodynamics in the distal end- to- side anastomosis is related to early development of intimal hyperplasia and bypass failure. In this study we investigated the effect of diameter ratios between the target artery and the bypass at three different angles of the connection. The pulsatile flow field was visualized using particle image velocimetry in transparent models with three different angles of the connection (25 degrees, 45 degrees, 60 degrees) and the diameter ratio between the bypass and the target artery was 4.6 mm : 6 mm, 6 mm : 6 mm, and 7.5 mm : 6 mm. Six parameters including location and oscillation of the stagnation point, local energy dissipation, wall shear stress (WSS), oscillatory shear index, spatial and temporal gradient of WSS and their distribution in the target artery were calculated from the flow field. In the wider bypass, the stagnation point oscillated in a greater range and was located more proximal to the anastomosis. Energy dissipation was minimal in a wider bypass with a more acute angle. The maximum WSS values were tree times greater in a narrow bypass and concentrated in a smaller circular region at the floor of the anastomosis. The oscillatory shear index increased with wider bypass and more acute angle. The maximum of spatial gradient of WSS concentrated around the floor and toe of the anastomosis and decreased with more acute angle and wider bypass, the temporal gradient of WSS was stretched more towards the side wall. Greater bypass to target vessel ratio and more acute anastomosis angle promote hemodynamics known to reduce formation of intimal hyperplasia.
Název v anglickém jazyce
The Ratio of Diameters Between the Target Artery and the Bypass Modifies Hemodynamic Parameters Related to Intimal Hyperplasia in the Distal End-to-Side Anastomosis
Popis výsledku anglicky
Hemodynamics in the distal end- to- side anastomosis is related to early development of intimal hyperplasia and bypass failure. In this study we investigated the effect of diameter ratios between the target artery and the bypass at three different angles of the connection. The pulsatile flow field was visualized using particle image velocimetry in transparent models with three different angles of the connection (25 degrees, 45 degrees, 60 degrees) and the diameter ratio between the bypass and the target artery was 4.6 mm : 6 mm, 6 mm : 6 mm, and 7.5 mm : 6 mm. Six parameters including location and oscillation of the stagnation point, local energy dissipation, wall shear stress (WSS), oscillatory shear index, spatial and temporal gradient of WSS and their distribution in the target artery were calculated from the flow field. In the wider bypass, the stagnation point oscillated in a greater range and was located more proximal to the anastomosis. Energy dissipation was minimal in a wider bypass with a more acute angle. The maximum WSS values were tree times greater in a narrow bypass and concentrated in a smaller circular region at the floor of the anastomosis. The oscillatory shear index increased with wider bypass and more acute angle. The maximum of spatial gradient of WSS concentrated around the floor and toe of the anastomosis and decreased with more acute angle and wider bypass, the temporal gradient of WSS was stretched more towards the side wall. Greater bypass to target vessel ratio and more acute anastomosis angle promote hemodynamics known to reduce formation of intimal hyperplasia.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Svazek periodika
65
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
901-908
Kód UT WoS článku
000391198200002
EID výsledku v databázi Scopus
2-s2.0-85011826465