Determination of retinoic acid in human serum and plasma by high-performance liquid chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10409783" target="_blank" >RIV/00064165:_____/19:10409783 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10409783
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=LvFF_nJ--Y" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=LvFF_nJ--Y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-019-02489-1" target="_blank" >10.1007/s00706-019-02489-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of retinoic acid in human serum and plasma by high-performance liquid chromatography
Popis výsledku v původním jazyce
All-trans retinoic acid (ATRA) is the main derivative of retinol. It is formed in the intestinal mucosa from retinaldehyde. The aim was to establish a high-performance liquid chromatography method for determination of ATRA in human serum and plasma. Stability of ATRA in serum stored under various conditions was tested as well. ATRA was extracted from serum (plasma) after deproteination with acetonitrile by hexan:ethylacetate mixture (50:50). The extract was then evaporated under nitrogen at room temperature and dissolved in methanol. ATRA was detected after separation on C18 column at 355 nm. This method uses acitretin as internal standard. Limit of detection was 0.21 µg/dm3 and limit of quantification 0.70 µg/dm3. The method is linear for ATRA concentration 0.78-25 µg/dm3. Based on our results, ATRA has the same concentration in serum and in plasma. Repeatability of the method measured within run is given by variation coefficient 4.31% for serum and 1.86% for plasma. Reproducibility of the method measured between runs is given by variation coefficient 9.55% for serum and 8.00% for plasma. The worst storage conditions were light and room temperature, ATRA decreased by 0.69 µg/dm3, i.e., by 39%. Simultaneously, with ATRA, retinol is measured as well. We have introduced a fast, simple, and reliable method for determination of ATRA in human serum and plasma.
Název v anglickém jazyce
Determination of retinoic acid in human serum and plasma by high-performance liquid chromatography
Popis výsledku anglicky
All-trans retinoic acid (ATRA) is the main derivative of retinol. It is formed in the intestinal mucosa from retinaldehyde. The aim was to establish a high-performance liquid chromatography method for determination of ATRA in human serum and plasma. Stability of ATRA in serum stored under various conditions was tested as well. ATRA was extracted from serum (plasma) after deproteination with acetonitrile by hexan:ethylacetate mixture (50:50). The extract was then evaporated under nitrogen at room temperature and dissolved in methanol. ATRA was detected after separation on C18 column at 355 nm. This method uses acitretin as internal standard. Limit of detection was 0.21 µg/dm3 and limit of quantification 0.70 µg/dm3. The method is linear for ATRA concentration 0.78-25 µg/dm3. Based on our results, ATRA has the same concentration in serum and in plasma. Repeatability of the method measured within run is given by variation coefficient 4.31% for serum and 1.86% for plasma. Reproducibility of the method measured between runs is given by variation coefficient 9.55% for serum and 8.00% for plasma. The worst storage conditions were light and room temperature, ATRA decreased by 0.69 µg/dm3, i.e., by 39%. Simultaneously, with ATRA, retinol is measured as well. We have introduced a fast, simple, and reliable method for determination of ATRA in human serum and plasma.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10608 - Biochemistry and molecular biology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
—
Svazek periodika
150
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
5
Strana od-do
1731-1735
Kód UT WoS článku
000514591400001
EID výsledku v databázi Scopus
2-s2.0-85074212172