Restoration of a Microdont Using the Resin Composite Injection Technique With a Fully Digital Workflow: A Flexible 3D-printed Index With a Stabilization Holder
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F23%3A10464789" target="_blank" >RIV/00064165:_____/23:10464789 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/23:10464789
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=evVHnNALbz" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=evVHnNALbz</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2341/23-007" target="_blank" >10.2341/23-007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Restoration of a Microdont Using the Resin Composite Injection Technique With a Fully Digital Workflow: A Flexible 3D-printed Index With a Stabilization Holder
Popis výsledku v původním jazyce
Direct composite restorations are accepted as a treatment option for microdontia, which is a relatively prevalent condition that poses esthetic concerns. While free-hand composite placement is technique sensitive and time-consuming, the resin composite injection technique is more straightforward and predictable. A fully digital workflow has been recently introduced, but the 3D-printed resin index is rigid to overcome undercuts, as opposed to the silicone index. This case report presents a flexible 3D-printed resin index, which can accurately transfer the digitally simulated functional and esthetic form to the final restoration. In addition, a rigid holding clip was designed to stabilize the flexible index.
Název v anglickém jazyce
Restoration of a Microdont Using the Resin Composite Injection Technique With a Fully Digital Workflow: A Flexible 3D-printed Index With a Stabilization Holder
Popis výsledku anglicky
Direct composite restorations are accepted as a treatment option for microdontia, which is a relatively prevalent condition that poses esthetic concerns. While free-hand composite placement is technique sensitive and time-consuming, the resin composite injection technique is more straightforward and predictable. A fully digital workflow has been recently introduced, but the 3D-printed resin index is rigid to overcome undercuts, as opposed to the silicone index. This case report presents a flexible 3D-printed resin index, which can accurately transfer the digitally simulated functional and esthetic form to the final restoration. In addition, a rigid holding clip was designed to stabilize the flexible index.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Operative Dentistry
ISSN
0361-7734
e-ISSN
1559-2863
Svazek periodika
48
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
483-489
Kód UT WoS článku
001081440900001
EID výsledku v databázi Scopus
2-s2.0-85171600859