A dual composite resin injection molding technique with 3D-printed flexible indices for biomimetic replacement of a missing mandibular lateral incisor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F24%3A10479976" target="_blank" >RIV/00064165:_____/24:10479976 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/24:10479976
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=jwYRI7gEUv" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=jwYRI7gEUv</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2186/jpr.JPR_D_23_00239" target="_blank" >10.2186/jpr.JPR_D_23_00239</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A dual composite resin injection molding technique with 3D-printed flexible indices for biomimetic replacement of a missing mandibular lateral incisor
Popis výsledku v původním jazyce
Patients: This case report presents a minimally invasive approach to replace a missing mandibular lateral incisor using a dual -injection molding technique with flowable composite resins. Integrated with a comprehensive digital workflow, this method achieves a structurally and esthetically biomimetic, bi-layered prosthetic solution. A 34-year-old woman with congenital absence of a mandibular lateral incisor was successfully rehabilitated using a direct composite resin-bonded fixed partial denture (RBFPD). Discussion: Two specialized three-dimensional (3D)-printed flexible indices stabilized by a custom-designed 3D-printed rigid holder were employed to ensure the meticulous injection molding of flowable composite resins formulated to emulate the inherent chromatic gradations between dentin and enamel. The inherent flexibility of the indices, combined with the holder, facilitated accurate and seamless adaptation to the complex morphological features of the dental arch, thereby mitigating the challenges commonly associated with rigid 3D-printed resin indices. Conclusions: The bilayered direct composite RBFPD using 3D printed flexible indices prepared with a full digital workflow has several advantages over other dental prosthetic solutions, including noninvasiveness, cost-effectiveness, biomimetic esthetics, repairability, and shortened treatment times. Although the initial results are promising, further longitudinal studies with larger patient cohorts are required to confirm the long-term efficacy of this approach.
Název v anglickém jazyce
A dual composite resin injection molding technique with 3D-printed flexible indices for biomimetic replacement of a missing mandibular lateral incisor
Popis výsledku anglicky
Patients: This case report presents a minimally invasive approach to replace a missing mandibular lateral incisor using a dual -injection molding technique with flowable composite resins. Integrated with a comprehensive digital workflow, this method achieves a structurally and esthetically biomimetic, bi-layered prosthetic solution. A 34-year-old woman with congenital absence of a mandibular lateral incisor was successfully rehabilitated using a direct composite resin-bonded fixed partial denture (RBFPD). Discussion: Two specialized three-dimensional (3D)-printed flexible indices stabilized by a custom-designed 3D-printed rigid holder were employed to ensure the meticulous injection molding of flowable composite resins formulated to emulate the inherent chromatic gradations between dentin and enamel. The inherent flexibility of the indices, combined with the holder, facilitated accurate and seamless adaptation to the complex morphological features of the dental arch, thereby mitigating the challenges commonly associated with rigid 3D-printed resin indices. Conclusions: The bilayered direct composite RBFPD using 3D printed flexible indices prepared with a full digital workflow has several advantages over other dental prosthetic solutions, including noninvasiveness, cost-effectiveness, biomimetic esthetics, repairability, and shortened treatment times. Although the initial results are promising, further longitudinal studies with larger patient cohorts are required to confirm the long-term efficacy of this approach.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Prosthodontic Research
ISSN
1883-1958
e-ISSN
1883-9207
Svazek periodika
68
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
JP - Japonsko
Počet stran výsledku
5
Strana od-do
667-671
Kód UT WoS článku
001184772200001
EID výsledku v databázi Scopus
2-s2.0-85200120340