[99mTc]Tc-Sestamibi/[99mTc]NaTcO4 Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F25%3A10503275" target="_blank" >RIV/00064165:_____/25:10503275 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/25:10503275 RIV/00064203:_____/25:10503275
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vSJFokzLxB" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vSJFokzLxB</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2967/jnmt.125.270082" target="_blank" >10.2967/jnmt.125.270082</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
[99mTc]Tc-Sestamibi/[99mTc]NaTcO4 Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components
Popis výsledku v původním jazyce
The aim of the study was to validate a new method for semiautomatic subtraction of [(99m)Tc]Tc-sestamibi and [(99m)Tc]NaTcO(4) SPECT 3-dimensional datasets using principal component analysis (PCA) against the results of parathyroid surgery and to compare its performance with an interactive method for visual comparison of images. We also sought to identify factors that affect the accuracy of lesion detection using the two methods. Methods: Scintigraphic data from [(99m)Tc]Tc-sestamibi and [(99m)Tc]NaTcO(4) SPECT were analyzed using semiautomatic subtraction of the 2 registered datasets based on PCA applied to the region of interest including the thyroid and an interactive method for visual comparison of the 2 image datasets. The findings of both methods were compared with those of surgery. Agreement with surgery was assessed with respect to the lesion quadrant, affected side of the neck, and the patient positivity regardless of location. Results: The results of parathyroid surgery and histology were available for 52 patients who underwent [(99m)Tc]Tc-sestamibi/[(99m)Tc]NaTcO(4) SPECT. Semiautomatic image subtraction identified the correct lesion quadrant in 46 patients (88%), the correct side of the neck in 51 patients (98%), and true pathologic lesions regardless of location in 51 patients (98%). Visual interactive analysis identified the correct lesion quadrant in 44 patients (85%), correct side of the neck in 49 patients (94%), and true pathologic lesions regardless of location in 50 patients (96%). There was no significant difference between the results of the 2 methods (P > 0.05). The factors supporting lesion detection were accurate positioning of the patient on the camera table, which facilitated subsequent image registration of the neck, and, after excluding ectopic parathyroid glands, focusing detection on the thyroid ROI. Conclusion: The results of semiautomatic subtraction of [(99m)Tc]Tc-sestamibi/[(99m)Tc]NaTcO(4) SPECT using PCA had good agreement with the findings from surgery as well as the visual interactive method, comparable to the high diagnostic accuracy of [(99m)Tc]Tc-sestamibi/[(123)I]NaI subtraction scintigraphy and [(18)F]fluorocholine PET/CT reported in the literature. The main advantages of semiautomatic subtraction are minimum user interaction and automatic adjustment of the subtraction weight. Principal component images may serve as optimized input objects, potentially useful in machine-learning algorithms aimed at fully automated detection of hyperfunctioning parathyroid glands.
Název v anglickém jazyce
[99mTc]Tc-Sestamibi/[99mTc]NaTcO4 Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components
Popis výsledku anglicky
The aim of the study was to validate a new method for semiautomatic subtraction of [(99m)Tc]Tc-sestamibi and [(99m)Tc]NaTcO(4) SPECT 3-dimensional datasets using principal component analysis (PCA) against the results of parathyroid surgery and to compare its performance with an interactive method for visual comparison of images. We also sought to identify factors that affect the accuracy of lesion detection using the two methods. Methods: Scintigraphic data from [(99m)Tc]Tc-sestamibi and [(99m)Tc]NaTcO(4) SPECT were analyzed using semiautomatic subtraction of the 2 registered datasets based on PCA applied to the region of interest including the thyroid and an interactive method for visual comparison of the 2 image datasets. The findings of both methods were compared with those of surgery. Agreement with surgery was assessed with respect to the lesion quadrant, affected side of the neck, and the patient positivity regardless of location. Results: The results of parathyroid surgery and histology were available for 52 patients who underwent [(99m)Tc]Tc-sestamibi/[(99m)Tc]NaTcO(4) SPECT. Semiautomatic image subtraction identified the correct lesion quadrant in 46 patients (88%), the correct side of the neck in 51 patients (98%), and true pathologic lesions regardless of location in 51 patients (98%). Visual interactive analysis identified the correct lesion quadrant in 44 patients (85%), correct side of the neck in 49 patients (94%), and true pathologic lesions regardless of location in 50 patients (96%). There was no significant difference between the results of the 2 methods (P > 0.05). The factors supporting lesion detection were accurate positioning of the patient on the camera table, which facilitated subsequent image registration of the neck, and, after excluding ectopic parathyroid glands, focusing detection on the thyroid ROI. Conclusion: The results of semiautomatic subtraction of [(99m)Tc]Tc-sestamibi/[(99m)Tc]NaTcO(4) SPECT using PCA had good agreement with the findings from surgery as well as the visual interactive method, comparable to the high diagnostic accuracy of [(99m)Tc]Tc-sestamibi/[(123)I]NaI subtraction scintigraphy and [(18)F]fluorocholine PET/CT reported in the literature. The main advantages of semiautomatic subtraction are minimum user interaction and automatic adjustment of the subtraction weight. Principal component images may serve as optimized input objects, potentially useful in machine-learning algorithms aimed at fully automated detection of hyperfunctioning parathyroid glands.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30202 - Endocrinology and metabolism (including diabetes, hormones)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nuclear Medicine Technology
ISSN
0091-4916
e-ISSN
1535-5675
Svazek periodika
53
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
318-324
Kód UT WoS článku
001644647800011
EID výsledku v databázi Scopus
2-s2.0-105023850767