Background/Objectives: Early localization of solitary pulmonary nodules (SPNs) remains challenging despite technological advances in endoscopic navigation, as the procedure often necessitates multiple ionizing imaging examinations. This study aimed to develop and evaluate a radiation-free optical method for SPN localization based on near-infrared (NIR) translumination. Methods: A miniaturized NIR light source was introduced into the bronchial tree to illuminate the lung parenchyma. The transmitted and scattered NIR light was detected in real time from the pleural side using minipleuroscopy and a CMOS camera. The approach exploits intrinsic differences in optical absorption and scattering between normal and pathological lung tissue, allowing visualization of the parenchymal micro-architecture without exogenous contrast agents. Results: In ex vivo porcine lungs, tissue structures were clearly visualized through up to approximately 4 cm of parenchyma. In a ventilated pig (n = 1), bronchial NIR illumination was consistently detected from the pleural cavity and produced distinct images of lobular structures and the bronchial mucosa. Conclusions: These feasibility findings demonstrate that NIR translumination can provide radiation-free intra-thoracic visualization and may serve as a valuable adjunct for biopsy guidance. Further quantitative validation and clinical translation are warranted to establish its applicability in human pulmonary procedures.
Název v anglickém jazyce
Non-Contrast Radiation-Free NIR Lung Imaging
Popis výsledku anglicky
Background/Objectives: Early localization of solitary pulmonary nodules (SPNs) remains challenging despite technological advances in endoscopic navigation, as the procedure often necessitates multiple ionizing imaging examinations. This study aimed to develop and evaluate a radiation-free optical method for SPN localization based on near-infrared (NIR) translumination. Methods: A miniaturized NIR light source was introduced into the bronchial tree to illuminate the lung parenchyma. The transmitted and scattered NIR light was detected in real time from the pleural side using minipleuroscopy and a CMOS camera. The approach exploits intrinsic differences in optical absorption and scattering between normal and pathological lung tissue, allowing visualization of the parenchymal micro-architecture without exogenous contrast agents. Results: In ex vivo porcine lungs, tissue structures were clearly visualized through up to approximately 4 cm of parenchyma. In a ventilated pig (n = 1), bronchial NIR illumination was consistently detected from the pleural cavity and produced distinct images of lobular structures and the bronchial mucosa. Conclusions: These feasibility findings demonstrate that NIR translumination can provide radiation-free intra-thoracic visualization and may serve as a valuable adjunct for biopsy guidance. Further quantitative validation and clinical translation are warranted to establish its applicability in human pulmonary procedures.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30203 - Respiratory systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedicines
ISSN
2227-9059
e-ISSN
2227-9059
Svazek periodika
13
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
16
Strana od-do
2757
Kód UT WoS článku
001624058300001
EID výsledku v databázi Scopus
2-s2.0-105023069736