Changes in heart rate variability in patients with atrial fibrillation after pulmonary vein isolation and ganglionated plexus ablation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F19%3AN0000074" target="_blank" >RIV/00064173:_____/19:N0000074 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/19:43917375
Výsledek na webu
<a href="https://doi.org/10.33549/physiolres.933710" target="_blank" >https://doi.org/10.33549/physiolres.933710</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.933710" target="_blank" >10.33549/physiolres.933710</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Changes in heart rate variability in patients with atrial fibrillation after pulmonary vein isolation and ganglionated plexus ablation
Popis výsledku v původním jazyce
Pulmonary vein isolation (PVI) is the cornerstone in the treatment of patients with paroxysmal atrial fibrillation (PAF). Some research has suggested studies have shown that modification of ganglionated plexuses (GP), performed with PVI, could lead to even better outcomes. The aim of this study was to determine the effect of PVI on the autonomic system. Heart rate variability (HRV) was used as a marker of autonomic system activity. Twenty-six PAF patients underwent PVI (PVI group) and twenty patients underwent PVI plus a GP ablation (GP group). In each group, 5 min long ECG signals obtained before and after the electrophysiology EP study were analyzed. Time and frequency domain parameters were evaluated. Vagal responses during ablation were observed in 15 (58 %) patients in the PVI group and in 12 (60 %) patients in the GP group. The change in normalized power in the low frequency (LF) and in the LF/HF ratio, before and after ablation, was statistically significant in both groups (LF/HF 2.6+/-1.6 before vs. 1.4+/-1.7 after ablation in PVI group and LF/HF 3.3+/-2.6 before vs.1.8+/-1.9 after ablation in the GP group). Relative to heart rate variability parameters, there were no differences between PVI and PVI + plus GP ablation.
Název v anglickém jazyce
Changes in heart rate variability in patients with atrial fibrillation after pulmonary vein isolation and ganglionated plexus ablation
Popis výsledku anglicky
Pulmonary vein isolation (PVI) is the cornerstone in the treatment of patients with paroxysmal atrial fibrillation (PAF). Some research has suggested studies have shown that modification of ganglionated plexuses (GP), performed with PVI, could lead to even better outcomes. The aim of this study was to determine the effect of PVI on the autonomic system. Heart rate variability (HRV) was used as a marker of autonomic system activity. Twenty-six PAF patients underwent PVI (PVI group) and twenty patients underwent PVI plus a GP ablation (GP group). In each group, 5 min long ECG signals obtained before and after the electrophysiology EP study were analyzed. Time and frequency domain parameters were evaluated. Vagal responses during ablation were observed in 15 (58 %) patients in the PVI group and in 12 (60 %) patients in the GP group. The change in normalized power in the low frequency (LF) and in the LF/HF ratio, before and after ablation, was statistically significant in both groups (LF/HF 2.6+/-1.6 before vs. 1.4+/-1.7 after ablation in PVI group and LF/HF 3.3+/-2.6 before vs.1.8+/-1.9 after ablation in the GP group). Relative to heart rate variability parameters, there were no differences between PVI and PVI + plus GP ablation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-32478A" target="_blank" >NV16-32478A: Projekt EndoMaze HYBRID- podrobné zhodnocení bezpečnosti a efektivity hybridní ablace perzistentní a dlouhodobě perzistentní fibrilace síní</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Svazek periodika
68
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
49-57
Kód UT WoS článku
000460617400005
EID výsledku v databázi Scopus
2-s2.0-85062692775