The absence of effect of ganglionated plexi ablation on heart rate variability parameters in patients after thoracoscopic ablation for atrial fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43916005" target="_blank" >RIV/00216208:11120/17:43916005 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/17:N0000006
Výsledek na webu
<a href="http://dx.doi.org/10.21037/jtd.2017.11.119" target="_blank" >http://dx.doi.org/10.21037/jtd.2017.11.119</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21037/jtd.2017.11.119" target="_blank" >10.21037/jtd.2017.11.119</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The absence of effect of ganglionated plexi ablation on heart rate variability parameters in patients after thoracoscopic ablation for atrial fibrillation
Popis výsledku v původním jazyce
Background: Hybrid ablation [thoracoscopic ablation (TA) of atrial fibrillation (AF) followed by catheter ablation (CA)] is an increasingly common method of the treatment for patients with AF. The aim of this study was to assess the response to ganglionated plexi (GP) ablation in patients with a previous TA (i.e., to assess whether TA had resulted in damage to the GP. Heart rate variability (HRV) was used as a marker of the autonomic response. Methods: Twenty AF patients underwent pulmonary vein isolation (PVI) plus GP ablation (GP group) and 18 AF patients underwent CA including GP ablation as a part of hybrid ablation (i.e., all patients had undergone a previous TA; Hybrid group). In each group, a 5 min electrocardiogram (ECG) obtained before and after the CA were analyzed. Time and frequency domain parameters were evaluated. Results: Vagal responses (VR) during CA were observed in 12 (60%) patients in the GP group; however, in the Hybrid group, VR was not observed in any of the patients during CA. The change in normalized power in the low frequency (LF) component and the ratio between the LF and high frequency (LF/HF ratio) components of the HRV spectra, before and after ablation, were statistically significant in the GP group (3.3+-2.6 before vs. 1.8+-1.9 after ablation) but unchanged, before or after CA, in the Hybrid group. Conclusions: GP ablation in patients subsequent to TA has a little influence on HRV parameters, which could be explained by GP damage during the preceding TA.
Název v anglickém jazyce
The absence of effect of ganglionated plexi ablation on heart rate variability parameters in patients after thoracoscopic ablation for atrial fibrillation
Popis výsledku anglicky
Background: Hybrid ablation [thoracoscopic ablation (TA) of atrial fibrillation (AF) followed by catheter ablation (CA)] is an increasingly common method of the treatment for patients with AF. The aim of this study was to assess the response to ganglionated plexi (GP) ablation in patients with a previous TA (i.e., to assess whether TA had resulted in damage to the GP. Heart rate variability (HRV) was used as a marker of the autonomic response. Methods: Twenty AF patients underwent pulmonary vein isolation (PVI) plus GP ablation (GP group) and 18 AF patients underwent CA including GP ablation as a part of hybrid ablation (i.e., all patients had undergone a previous TA; Hybrid group). In each group, a 5 min electrocardiogram (ECG) obtained before and after the CA were analyzed. Time and frequency domain parameters were evaluated. Results: Vagal responses (VR) during CA were observed in 12 (60%) patients in the GP group; however, in the Hybrid group, VR was not observed in any of the patients during CA. The change in normalized power in the low frequency (LF) component and the ratio between the LF and high frequency (LF/HF ratio) components of the HRV spectra, before and after ablation, were statistically significant in the GP group (3.3+-2.6 before vs. 1.8+-1.9 after ablation) but unchanged, before or after CA, in the Hybrid group. Conclusions: GP ablation in patients subsequent to TA has a little influence on HRV parameters, which could be explained by GP damage during the preceding TA.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-32478A" target="_blank" >NV16-32478A: Projekt EndoMaze HYBRID- podrobné zhodnocení bezpečnosti a efektivity hybridní ablace perzistentní a dlouhodobě perzistentní fibrilace síní</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Thoracic Disease
ISSN
2072-1439
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CN - Čínská lidová republika
Počet stran výsledku
11
Strana od-do
4997-5007
Kód UT WoS článku
000419323400074
EID výsledku v databázi Scopus
2-s2.0-85039798599