The Efficacy of Fibrin Sealant in Sutureless Deep Sclerectomy - Preliminary Outcomes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F24%3A43926901" target="_blank" >RIV/00064173:_____/24:43926901 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/24:43926901
Výsledek na webu
<a href="https://doi.org/10.1097/IJG.0000000000002380" target="_blank" >https://doi.org/10.1097/IJG.0000000000002380</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/IJG.0000000000002380" target="_blank" >10.1097/IJG.0000000000002380</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Efficacy of Fibrin Sealant in Sutureless Deep Sclerectomy - Preliminary Outcomes
Popis výsledku v původním jazyce
PRCIS: Deep sclerectomy with fibrin adhesive can constitute a safe alternative to the classic procedure using sutures, providing non-allergenic, non-toxic and secure adhesion with no sign of aqueous humor outflow obstruction postoperatively. PURPOSE: To evaluate short- and medium-term postoperative results of deep sclerectomy (DS) with a fibrin sealant. PATIENTS AND METHODS: This prospective, noncomparative, interventional case-series involves 12 eyes of 12 patients with uncontrolled open-angle glaucoma (OAG) who underwent DS with Esnoper (Clip or V2000) implant between February 2021 and March 2022. A novel method of wound closure (sclera, Tenon's fascia and conjunctiva) employing fibrin glue was used instead of classic sutures. Surgical outcomes assessed include: intraocular pressure (IOP) and glaucoma therapy (GT) reduction, best-corrected visual acuity (BCVA) changes and number of complications registered peri- and postoperatively. All measurements were performed preoperatively, as well as at 1 day, at 1 and 2 weeks, and at 1, 2, 3, 6, 9 and 12 months after surgery. RESULTS: The mean IOP decreased from 24.0+-9.1 mmHg to 13.8+-6.3 mmHg at one year postoperatively (P<0.001). Kaplan-Meier survival analysis revealed complete and qualified success rates of 83.3% and 91.7%. The mean GT decreased from 3.2+-1.1 to 0.8+-1.3 drugs 12 months after surgery (P<0.001). Nd:YAG goniopunture was performed in 2 eyes at 1 and 12 months postoperatively. No significant BCVA changes were registered. Perioperatively, we noted a trabeculo-descemet microperforation in one eye, transient hypotony in 5 eyes and mild hyphema in 2 eyes. CONCLUSIONS: Fibrin adhesive provided an effective closure in sutureless DS in the patients included in our study. This modification of classical DS may simplify the surgical technique, ensure secure wound adaptation, optimize healing, and lower the risk of inflammation and fibrosis postoperatively.
Název v anglickém jazyce
The Efficacy of Fibrin Sealant in Sutureless Deep Sclerectomy - Preliminary Outcomes
Popis výsledku anglicky
PRCIS: Deep sclerectomy with fibrin adhesive can constitute a safe alternative to the classic procedure using sutures, providing non-allergenic, non-toxic and secure adhesion with no sign of aqueous humor outflow obstruction postoperatively. PURPOSE: To evaluate short- and medium-term postoperative results of deep sclerectomy (DS) with a fibrin sealant. PATIENTS AND METHODS: This prospective, noncomparative, interventional case-series involves 12 eyes of 12 patients with uncontrolled open-angle glaucoma (OAG) who underwent DS with Esnoper (Clip or V2000) implant between February 2021 and March 2022. A novel method of wound closure (sclera, Tenon's fascia and conjunctiva) employing fibrin glue was used instead of classic sutures. Surgical outcomes assessed include: intraocular pressure (IOP) and glaucoma therapy (GT) reduction, best-corrected visual acuity (BCVA) changes and number of complications registered peri- and postoperatively. All measurements were performed preoperatively, as well as at 1 day, at 1 and 2 weeks, and at 1, 2, 3, 6, 9 and 12 months after surgery. RESULTS: The mean IOP decreased from 24.0+-9.1 mmHg to 13.8+-6.3 mmHg at one year postoperatively (P<0.001). Kaplan-Meier survival analysis revealed complete and qualified success rates of 83.3% and 91.7%. The mean GT decreased from 3.2+-1.1 to 0.8+-1.3 drugs 12 months after surgery (P<0.001). Nd:YAG goniopunture was performed in 2 eyes at 1 and 12 months postoperatively. No significant BCVA changes were registered. Perioperatively, we noted a trabeculo-descemet microperforation in one eye, transient hypotony in 5 eyes and mild hyphema in 2 eyes. CONCLUSIONS: Fibrin adhesive provided an effective closure in sutureless DS in the patients included in our study. This modification of classical DS may simplify the surgical technique, ensure secure wound adaptation, optimize healing, and lower the risk of inflammation and fibrosis postoperatively.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Glaucoma
ISSN
1057-0829
e-ISSN
1536-481X
Svazek periodika
33
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
686-695
Kód UT WoS článku
001301020800005
EID výsledku v databázi Scopus
2-s2.0-85202906311