Femoral arterial cannulation for surgical repair of stanford type A aortic dissection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F24%3A43926983" target="_blank" >RIV/00064173:_____/24:43926983 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/24:43926983
Výsledek na webu
<a href="https://doi.org/10.1002/wjs.12203" target="_blank" >https://doi.org/10.1002/wjs.12203</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/wjs.12203" target="_blank" >10.1002/wjs.12203</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Femoral arterial cannulation for surgical repair of stanford type A aortic dissection
Popis výsledku v původním jazyce
BACKGROUND: The benefits and harms associated with femoral artery cannulation over other sites of arterial cannulation for surgical repair of acute Stanford type A aortic dissection (TAAD) are not conclusively established. METHODS: We evaluated the outcomes after surgery for TAAD using femoral artery cannulation, supra-aortic arterial cannulation (i.e., innominate/subclavian/axillary artery cannulation), and direct aortic cannulation. RESULTS: 3751 (96.1%) patients were eligible for this analysis. In-hospital mortality using supra-aortic arterial cannulation was comparable to femoral artery cannulation (17.8% vs. 18.4%; adjusted OR 0.846, 95% CI 0.799-1.202). This finding was confirmed in 1028 propensity score-matched pairs of patients with supra-aortic arterial cannulation or femoral artery cannulation (17.5% vs. 17.0%, p = 0.770). In-hospital mortality after direct aortic cannulation was lower compared to femoral artery cannulation (14.0% vs. 18.4%, adjusted OR 0.703, 95% CI 0.529-0.934). Among 583 propensity score-matched pairs of patients, direct aortic cannulation was associated with lower rates of in-hospital mortality (13.4% vs. 19.6%, p = 0.004) compared to femoral artery cannulation. Switching of the primary site of arterial cannulation was associated with increased rate of in-hospital mortality (36.5% vs. 17.0%; adjusted OR 2.730, 95% CI 1.564-4.765). Ten-year mortality was similar in the study cohorts. CONCLUSIONS: In this study, the outcomes of surgery for TAAD using femoral arterial cannulation were comparable to those using supra-aortic arterial cannulation. However, femoral arterial cannulation was associated with higher in-hospital mortality than direct aortic cannulation. TRIAL REGISTRATION: ClinicalTrials.gov registration code: NCT04831073.
Název v anglickém jazyce
Femoral arterial cannulation for surgical repair of stanford type A aortic dissection
Popis výsledku anglicky
BACKGROUND: The benefits and harms associated with femoral artery cannulation over other sites of arterial cannulation for surgical repair of acute Stanford type A aortic dissection (TAAD) are not conclusively established. METHODS: We evaluated the outcomes after surgery for TAAD using femoral artery cannulation, supra-aortic arterial cannulation (i.e., innominate/subclavian/axillary artery cannulation), and direct aortic cannulation. RESULTS: 3751 (96.1%) patients were eligible for this analysis. In-hospital mortality using supra-aortic arterial cannulation was comparable to femoral artery cannulation (17.8% vs. 18.4%; adjusted OR 0.846, 95% CI 0.799-1.202). This finding was confirmed in 1028 propensity score-matched pairs of patients with supra-aortic arterial cannulation or femoral artery cannulation (17.5% vs. 17.0%, p = 0.770). In-hospital mortality after direct aortic cannulation was lower compared to femoral artery cannulation (14.0% vs. 18.4%, adjusted OR 0.703, 95% CI 0.529-0.934). Among 583 propensity score-matched pairs of patients, direct aortic cannulation was associated with lower rates of in-hospital mortality (13.4% vs. 19.6%, p = 0.004) compared to femoral artery cannulation. Switching of the primary site of arterial cannulation was associated with increased rate of in-hospital mortality (36.5% vs. 17.0%; adjusted OR 2.730, 95% CI 1.564-4.765). Ten-year mortality was similar in the study cohorts. CONCLUSIONS: In this study, the outcomes of surgery for TAAD using femoral arterial cannulation were comparable to those using supra-aortic arterial cannulation. However, femoral arterial cannulation was associated with higher in-hospital mortality than direct aortic cannulation. TRIAL REGISTRATION: ClinicalTrials.gov registration code: NCT04831073.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
World Journal of Surgery
ISSN
0364-2313
e-ISSN
1432-2323
Svazek periodika
48
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1771-1782
Kód UT WoS článku
001209604400001
EID výsledku v databázi Scopus
2-s2.0-85192101407