Comparing Effectiveness and Safety of Left Atrial Appendage Closure Devices: A Network Meta-Analysis of Randomized Controlled Trials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F25%3A43929088" target="_blank" >RIV/00064173:_____/25:43929088 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/25:43929088
Výsledek na webu
<a href="https://doi.org/10.1002/clc.70217" target="_blank" >https://doi.org/10.1002/clc.70217</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/clc.70217" target="_blank" >10.1002/clc.70217</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparing Effectiveness and Safety of Left Atrial Appendage Closure Devices: A Network Meta-Analysis of Randomized Controlled Trials
Popis výsledku v původním jazyce
INTRODUCTION: Atrial fibrillation-related stroke is a leading cause of morbidity and mortality. The comparative effectiveness and safety of left atrial appendage closure (LAAC) devices, compared with one another and with anticoagulation, is unclear. METHODS: We conducted a systematic review and network meta-analysis (NMA) of all clinical trials comparing the Watchman and Amplatzer Amulet LAAC devices with each other or with warfarin or direct oral anticoagulants (DOACs). The primary comparison was between LAAC devices with secondary comparisons to anticoagulation. The primary effectiveness outcomes were any stroke and all-cause death. Safety outcomes included any thromboembolism, device embolization, and pericardial effusion. RESULTS: There were 476 articles identified from the search and 6 eligible RCTs were included (n = 3666). There was no difference in the risk of stroke with Amulet versus Watchman (RR = 1.48, 95% CI: 0.64-3.46, I(2) = 41.3%), nor in the risk of death (RR = 1.00, 95% CI: 0.59-1.70, I(2) = 45.0%). Risk of thromboembolism was not significantly different with Amulet versus Watchman (RR = 0.73, 95% CI: 0.18-2.97, I(2) = 0%), nor was risk of device embolization (RR = 2.29, 95% CI: 0.71, 7.43, I(2) = 0%). Both devices exhibited increased risk of pericardial effusion compared with warfarin, with Amulet at highest relative risk (RR = 27.08, 95% CI: 3.53-207.98, I(2) = 0%) followed by Watchman (RR = 12.79, 95% CI: 1.73-94.85, I(2) = 0%). Amulet also carried higher relative risk of pericardial effusion than Watchman (RR = 2.12, 95% CI: 1.45-3.09). CONCLUSION: In this NMA, the Amulet and Watchman LAAC devices were associated with similar risks for stroke, mortality, thromboembolism, and device embolization. Pericardial effusion risk was higher with Amulet than Watchman.
Název v anglickém jazyce
Comparing Effectiveness and Safety of Left Atrial Appendage Closure Devices: A Network Meta-Analysis of Randomized Controlled Trials
Popis výsledku anglicky
INTRODUCTION: Atrial fibrillation-related stroke is a leading cause of morbidity and mortality. The comparative effectiveness and safety of left atrial appendage closure (LAAC) devices, compared with one another and with anticoagulation, is unclear. METHODS: We conducted a systematic review and network meta-analysis (NMA) of all clinical trials comparing the Watchman and Amplatzer Amulet LAAC devices with each other or with warfarin or direct oral anticoagulants (DOACs). The primary comparison was between LAAC devices with secondary comparisons to anticoagulation. The primary effectiveness outcomes were any stroke and all-cause death. Safety outcomes included any thromboembolism, device embolization, and pericardial effusion. RESULTS: There were 476 articles identified from the search and 6 eligible RCTs were included (n = 3666). There was no difference in the risk of stroke with Amulet versus Watchman (RR = 1.48, 95% CI: 0.64-3.46, I(2) = 41.3%), nor in the risk of death (RR = 1.00, 95% CI: 0.59-1.70, I(2) = 45.0%). Risk of thromboembolism was not significantly different with Amulet versus Watchman (RR = 0.73, 95% CI: 0.18-2.97, I(2) = 0%), nor was risk of device embolization (RR = 2.29, 95% CI: 0.71, 7.43, I(2) = 0%). Both devices exhibited increased risk of pericardial effusion compared with warfarin, with Amulet at highest relative risk (RR = 27.08, 95% CI: 3.53-207.98, I(2) = 0%) followed by Watchman (RR = 12.79, 95% CI: 1.73-94.85, I(2) = 0%). Amulet also carried higher relative risk of pericardial effusion than Watchman (RR = 2.12, 95% CI: 1.45-3.09). CONCLUSION: In this NMA, the Amulet and Watchman LAAC devices were associated with similar risks for stroke, mortality, thromboembolism, and device embolization. Pericardial effusion risk was higher with Amulet than Watchman.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Cardiology
ISSN
0160-9289
e-ISSN
1932-8737
Svazek periodika
48
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
"e70217"
Kód UT WoS článku
001620104800001
EID výsledku v databázi Scopus
2-s2.0-105022638540