Validation of the Skin Prick Automated Test (SPAT) Cut-Off Value in Birch Pollen and House Dust Mite Allergic Rhinitis Patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064190%3A_____%2F25%3A10001381" target="_blank" >RIV/00064190:_____/25:10001381 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/25:10500087
Výsledek na webu
<a href="https://doi.org/10.1111/all.16645" target="_blank" >https://doi.org/10.1111/all.16645</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/all.16645" target="_blank" >10.1111/all.16645</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Validation of the Skin Prick Automated Test (SPAT) Cut-Off Value in Birch Pollen and House Dust Mite Allergic Rhinitis Patients
Popis výsledku v původním jazyce
IntroductionA novel device, Skin Prick Automated Test (SPAT), previously showed reduced variability and more consistent test results compared to conventional skin prick test (SPT) to identify allergic sensitisation. This study aimed to clinically validate the adjusted SPAT cut-off in patients with confirmed birch or house dust mite (HDM) allergy.MethodsSeventy-five adults were included: 25 non-allergic subjects (confirmed by lack of allergy history and negative SPT), 25 birch and 25 HDM allergic rhinitis patients (both confirmed by positive SPT and nasal allergen challenge [NAC]). All subjects received a conventional SPT and an automated SPT for B ver, D pter, D far and control solutions.ResultsA cut-off of 4.2 and 4.1 mm, respectively, resulted in the highest accuracy to detect birch or HDM allergy using SPAT. Referring to previous study results suggesting a reliable cut-off value of 4.5 mm, it was decided to maintain 4.5 mm as SPAT cut-off indicating allergic sensitisation. Accuracy did not significantly differ between SPAT (96% using >=$$ ge $$ 4.5 mm) and conventional SPT (98% using >=$$ ge $$ 3.0 mm) to detect HDM allergy or to detect birch pollen allergy (100% for SPAT and SPT). SPAT wheal measurements performed through a ruler on the forearm or through digital measurement on a composite image did not significantly differ for any of the patient groups analysed.ConclusionSPAT showed an equivalent accuracy to detect birch pollen or HDM allergy compared to conventional SPT, using the adjusted 4.5 mm SPAT cut-off in patients with confirmed allergic rhinitis. The SPAT web viewer can be used easily and effectively for digital wheal measurement on a composite image.
Název v anglickém jazyce
Validation of the Skin Prick Automated Test (SPAT) Cut-Off Value in Birch Pollen and House Dust Mite Allergic Rhinitis Patients
Popis výsledku anglicky
IntroductionA novel device, Skin Prick Automated Test (SPAT), previously showed reduced variability and more consistent test results compared to conventional skin prick test (SPT) to identify allergic sensitisation. This study aimed to clinically validate the adjusted SPAT cut-off in patients with confirmed birch or house dust mite (HDM) allergy.MethodsSeventy-five adults were included: 25 non-allergic subjects (confirmed by lack of allergy history and negative SPT), 25 birch and 25 HDM allergic rhinitis patients (both confirmed by positive SPT and nasal allergen challenge [NAC]). All subjects received a conventional SPT and an automated SPT for B ver, D pter, D far and control solutions.ResultsA cut-off of 4.2 and 4.1 mm, respectively, resulted in the highest accuracy to detect birch or HDM allergy using SPAT. Referring to previous study results suggesting a reliable cut-off value of 4.5 mm, it was decided to maintain 4.5 mm as SPAT cut-off indicating allergic sensitisation. Accuracy did not significantly differ between SPAT (96% using >=$$ ge $$ 4.5 mm) and conventional SPT (98% using >=$$ ge $$ 3.0 mm) to detect HDM allergy or to detect birch pollen allergy (100% for SPAT and SPT). SPAT wheal measurements performed through a ruler on the forearm or through digital measurement on a composite image did not significantly differ for any of the patient groups analysed.ConclusionSPAT showed an equivalent accuracy to detect birch pollen or HDM allergy compared to conventional SPT, using the adjusted 4.5 mm SPAT cut-off in patients with confirmed allergic rhinitis. The SPAT web viewer can be used easily and effectively for digital wheal measurement on a composite image.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30225 - Allergy
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ALLERGY
ISSN
0105-4538
e-ISSN
1398-9995
Svazek periodika
80
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
nestránkováno
Kód UT WoS článku
001524643100001
EID výsledku v databázi Scopus
2-s2.0-105010053877