Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F13%3A10209753" target="_blank" >RIV/00064203:_____/13:10209753 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/13:10209753
Výsledek na webu
<a href="http://dx.doi.org/10.1089/dia.2012.0235" target="_blank" >http://dx.doi.org/10.1089/dia.2012.0235</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1089/dia.2012.0235" target="_blank" >10.1089/dia.2012.0235</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
Popis výsledku v původním jazyce
Background: The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear (R) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and type 2 diabetes mellitus while walking on a treadmill. Subjects and Methods: In total, six men (60.3 +/- 3.1 years old) and 13 women (51.1 +/- 11.0 years old) with type 1 or type 2 diabetes mellitus were included in the study. Each subject performed three 15-min walking sessions with different combinations of speed and incline (3 km/h, 0%; 4 km/h, 0%; 5 km/h, 5%) on a treadmill. Energy expenditure (EE) was simultaneously measured by theSWA, Omron, and IC. Mean over-/underestimation and Pearson's correlation coefficients were used for statistical evaluation of the agreement between tested methods and IC. Results: At the speed of 3 km/h with 0% incline, mean overestimatio
Název v anglickém jazyce
Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
Popis výsledku anglicky
Background: The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear (R) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and type 2 diabetes mellitus while walking on a treadmill. Subjects and Methods: In total, six men (60.3 +/- 3.1 years old) and 13 women (51.1 +/- 11.0 years old) with type 1 or type 2 diabetes mellitus were included in the study. Each subject performed three 15-min walking sessions with different combinations of speed and incline (3 km/h, 0%; 4 km/h, 0%; 5 km/h, 5%) on a treadmill. Energy expenditure (EE) was simultaneously measured by theSWA, Omron, and IC. Mean over-/underestimation and Pearson's correlation coefficients were used for statistical evaluation of the agreement between tested methods and IC. Results: At the speed of 3 km/h with 0% incline, mean overestimatio
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FB - Endokrinologie, diabetologie, metabolismus, výživa
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Diabetes Technology and Therapeutics
ISSN
1520-9156
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
413-418
Kód UT WoS článku
000318477700009
EID výsledku v databázi Scopus
—