Comparative measurement of the head orientation using camera system and gyroscope system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F14%3A10293721" target="_blank" >RIV/00064203:_____/14:10293721 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/14:00222803 RIV/00216208:11130/14:10293721
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-00846-2_375" target="_blank" >http://dx.doi.org/10.1007/978-3-319-00846-2_375</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-00846-2_375" target="_blank" >10.1007/978-3-319-00846-2_375</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparative measurement of the head orientation using camera system and gyroscope system
Popis výsledku v původním jazyce
The aim of article is to compare two fundamentally different MoCap systems used to measure head orientation. We used IR medical camera and one 3DOF orientation tracker placed on subject's head and measured 3-D data - inclination (roll), flexion (pitch) and rotation (yaw). The volumes of 3D confidence ellipsoids were used to compare the two systems. Using the volumes of confidence ellipsoids, we were able to model the distribution of the measured 3-D data. Ten healthy subjects in the study were measuredand statistical analysis was performed. The results of the comparative method based on the confidence ellipsoid show that the volumes related to the 3DOF orientation tracker are significantly larger than the volumes related to the IR medical camera. Although the results are different when using different MoCap systems, the MoCap systems identified the same subject's behavior and deterioration or improvement of stability. The comparative measurement based on concept of confidence ellipsoi
Název v anglickém jazyce
Comparative measurement of the head orientation using camera system and gyroscope system
Popis výsledku anglicky
The aim of article is to compare two fundamentally different MoCap systems used to measure head orientation. We used IR medical camera and one 3DOF orientation tracker placed on subject's head and measured 3-D data - inclination (roll), flexion (pitch) and rotation (yaw). The volumes of 3D confidence ellipsoids were used to compare the two systems. Using the volumes of confidence ellipsoids, we were able to model the distribution of the measured 3-D data. Ten healthy subjects in the study were measuredand statistical analysis was performed. The results of the comparative method based on the confidence ellipsoid show that the volumes related to the 3DOF orientation tracker are significantly larger than the volumes related to the IR medical camera. Although the results are different when using different MoCap systems, the MoCap systems identified the same subject's behavior and deterioration or improvement of stability. The comparative measurement based on concept of confidence ellipsoi
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013
ISBN
978-3-319-00845-5
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1519-1522
Název nakladatele
Springer International Publishing
Místo vydání
Switzerland
Místo konání akce
Sevilla
Datum konání akce
25. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—