Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F16%3A10332538" target="_blank" >RIV/00064203:_____/16:10332538 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/27283933:_____/16:N0000022
Výsledek na webu
<a href="http://dx.doi.org/10.3171/2016.3.SPINE15810" target="_blank" >http://dx.doi.org/10.3171/2016.3.SPINE15810</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3171/2016.3.SPINE15810" target="_blank" >10.3171/2016.3.SPINE15810</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome
Popis výsledku v původním jazyce
OBJECTIVE Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from -2.4 degrees preoperatively to -6.2 degrees at 4 years, and postoperative height was maintained during the follow-up.
Název v anglickém jazyce
Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome
Popis výsledku anglicky
OBJECTIVE Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from -2.4 degrees preoperatively to -6.2 degrees at 4 years, and postoperative height was maintained during the follow-up.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Neurosurgery: Spine
ISSN
1547-5654
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
556-565
Kód UT WoS článku
000386106400002
EID výsledku v databázi Scopus
2-s2.0-85012839676