Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F19%3A10395254" target="_blank" >RIV/00064203:_____/19:10395254 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/86652052:_____/19:N0000003
Výsledek na webu
<a href="https://doi.org/10.1088/1742-6596/1248/1/012046" target="_blank" >https://doi.org/10.1088/1742-6596/1248/1/012046</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/1248/1/012046" target="_blank" >10.1088/1742-6596/1248/1/012046</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Popis výsledku v původním jazyce
Six different phantoms (2x CIRS, 1x Agmeco, 1x QUASAR, 1x Gammex, 1x CatPhan) and Varian formulas were used to evaluate their suitability for CT numbers to relative electron density (RED) calibration in the treatment planning system at two centres using two CT scanners. The variability in calibration curve and the influence to dose calculation in the TPS were estimated for 6 MV and 18 MV. The presence of scattering material around inhomogeneities and influence of CT spectra (90 kV, 120 kV, 140 kV) were evaluated. All phantoms were found convenient for calibration except CatPhan where large deviations were observed for dense bone. Phantoms without scatter material around inhomogeneities should be used with caution. Varian formula slightly overestimates calibration curve in the region of 200 - 300 HU. The tolerance level of 10% suggested for RED during commissioning is reasonable as it can cause change in dose of 3% and 1.5% for 6 MV and 18 MV respectively as a very conservative estimate. Calibration curves should be acquired for all scanning protocols with different CT spectra.
Název v anglickém jazyce
Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Popis výsledku anglicky
Six different phantoms (2x CIRS, 1x Agmeco, 1x QUASAR, 1x Gammex, 1x CatPhan) and Varian formulas were used to evaluate their suitability for CT numbers to relative electron density (RED) calibration in the treatment planning system at two centres using two CT scanners. The variability in calibration curve and the influence to dose calculation in the TPS were estimated for 6 MV and 18 MV. The presence of scattering material around inhomogeneities and influence of CT spectra (90 kV, 120 kV, 140 kV) were evaluated. All phantoms were found convenient for calibration except CatPhan where large deviations were observed for dense bone. Phantoms without scatter material around inhomogeneities should be used with caution. Varian formula slightly overestimates calibration curve in the region of 200 - 300 HU. The tolerance level of 10% suggested for RED during commissioning is reasonable as it can cause change in dose of 3% and 1.5% for 6 MV and 18 MV respectively as a very conservative estimate. Calibration curves should be acquired for all scanning protocols with different CT spectra.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Physics: Conference Series
ISBN
—
ISSN
1742-6588
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institute of Physics Publishing
Místo vydání
Bristol
Místo konání akce
Kuala Lumpur
Datum konání akce
11. 11. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000492968100046