Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000003" target="_blank" >RIV/86652052:_____/19:N0000003 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/19:10395254
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012046/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012046/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/1248/1/012046" target="_blank" >10.1088/1742-6596/1248/1/012046</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Popis výsledku v původním jazyce
Calibration curves from CT numbers to electron/physical densities in treatment planning systems (TPS) is an important part of commissioning. The aim of this work was to compare phantoms manufactured by different vendors. 6 phantoms were included in the study (2x CIRS, 1x Agmeco, 1x QUASAR, 1x Gammex, 1x CatPhan) to evaluate the sensitivity of dose calculated by TPS to calibration curve. All phantoms were scanned at two centres with 2 CT scanners under different protocols with various kV. The influence of different calibration curves on dose calculation in the TPS has been estimated. The presence of titanium and the scattering material has been evaluated. The sensitivity of RED to dose is higher for CT numbers higher than 100 HU (10% change in RED caused 3% and 1,5% in dose for 6MV and 18 MV respectively for material of 10 cm thickness). The largest sensitivity was observed for dense bone (up to 3,5% in dose for 6MV). The CT spectra can influence doses up to 4,5% and 2,5% for 6MV and 18 MV respectively. Two phantoms by the same vendor differed for dense bone up to 2% and 1% in dose for 6MV and 18 MV respectively. Phantoms used for CT-RED calibration were compared and various conditions and their influence to dose calculated by TPS was evaluated.
Název v anglickém jazyce
Inter-comparison of phantoms for CT numbers to relative electron density (RED)/physical density calibration and influence to dose calculation in TPS
Popis výsledku anglicky
Calibration curves from CT numbers to electron/physical densities in treatment planning systems (TPS) is an important part of commissioning. The aim of this work was to compare phantoms manufactured by different vendors. 6 phantoms were included in the study (2x CIRS, 1x Agmeco, 1x QUASAR, 1x Gammex, 1x CatPhan) to evaluate the sensitivity of dose calculated by TPS to calibration curve. All phantoms were scanned at two centres with 2 CT scanners under different protocols with various kV. The influence of different calibration curves on dose calculation in the TPS has been estimated. The presence of titanium and the scattering material has been evaluated. The sensitivity of RED to dose is higher for CT numbers higher than 100 HU (10% change in RED caused 3% and 1,5% in dose for 6MV and 18 MV respectively for material of 10 cm thickness). The largest sensitivity was observed for dense bone (up to 3,5% in dose for 6MV). The CT spectra can influence doses up to 4,5% and 2,5% for 6MV and 18 MV respectively. Two phantoms by the same vendor differed for dense bone up to 2% and 1% in dose for 6MV and 18 MV respectively. Phantoms used for CT-RED calibration were compared and various conditions and their influence to dose calculated by TPS was evaluated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FV20411" target="_blank" >FV20411: Radioterapeutický plánovací systém - optimalizace nejmodernějších algoritmů pro 3D výpočet dávky od externích svazků v těle pacienta a jejich integrace do nové generace plánovacího systému.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Physics Conference Series, 18th Asia-Oceania Congress of Medical Physics (AOCMP) / 16th South-East Asia Congress of Medical Physics (SEACOMP)
ISBN
—
ISSN
1742-6588
e-ISSN
1742-6596
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IOP PUBLISHING
Místo vydání
Bristol
Místo konání akce
Kuala Lumpur, MALAYSIA
Datum konání akce
11. 11. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000492968100046