Correlation between palpatory assessment and pressure sensors in response to postural trunk tests
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F21%3A10429916" target="_blank" >RIV/00064203:_____/21:10429916 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/21:10429916 RIV/49777513:23310/21:43962951
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=nxOarIHArB" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=nxOarIHArB</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3233/IES-205238" target="_blank" >10.3233/IES-205238</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correlation between palpatory assessment and pressure sensors in response to postural trunk tests
Popis výsledku v původním jazyce
BACKGROUND: The evaluation of postural trunk muscle function is a critical component of clinical assessment in patients with musculoskeletal pain and dysfunction. Postural activation of the trunk muscles has been evaluated by various methods. This study evaluates the correlation between subjective assessment of postural trunk muscle function with an objective measurement of abdominal wall expansion. METHODS: Twenty-five healthy participants (16 women, 9 men, age 22.4 years) were assessed. The subjective assessment was performed by two experienced Dynamic Neuromuscular Stabilization (DNS) clinicians evaluating the quality of trunk stabilization using five postural stability tests through palpation and observation. Interrater reliability was determined using an intraclass correlation coefficients (ICC). Objective measurement was performed using a new device (DNS Brace) which externally measures abdominal wall pressure. Spearman rank correlations were calculated for both palpation and observation measures with DNS Brace data. RESULTS: The interrater reliability (ICC2,k) estimates demonstrated moderate reliability in palpation measures for three DNS tests: Hip flexion test, Diaphragm test, & Intra-abdominal pressure regulation test (IAPRT) (ICC = 0.645-0.707). For observation measures, good reliability was found in IAPRT (ICC = 0.835), and three tests demonstrated moderate reliability: Hip flexion test, Diaphragm test, & Breathing Stereotype (ICC = 0.577-0.695). Correlation analysis demonstrated several moderate to strong correlations between palpation and DNS brace values (Assessor 1): IAPRT, rs= 0.580, p= 0.002, Diaphragm test, rs= 0.543, p= 0.005, (Assessor 2): IAPRT, rs= 0.776, p< 0.001, Breathing Stereotype, rs= 0.625, p= 0.001, Diaphragm test, rs= 0.519, p= 0.008, Hip Flexion test, rs= 0.536, p= 0.006, and Arm Elevation test, rs= 0.460, p= 0.021. For observation, several moderate correlations were demonstrated with DNS brace values (Assessor 1): Arm Elevation test, rs= 0.472, p= 0.017, (Assessor 2) Diaphragm test, rs= 0.540, p= 0.005, IAPRT rs= 0.475, p= 0.016, Hip Flexion test, rs= 0.485, p= 0.014, and Arm Elevation, rs= 0.451, p= 0.024. CONCLUSION: Based on inter-rater reliability and DNS brace correlations with trained DNS professionals, the IAPRT, Diaphragm test, and Hip Flexion test may prove useful when assessing asymptomatic individuals. More research is needed in order to establish the utility of DNS brace and clinical testing both in asymptomatic and back pain populations. DNS tests must be supplemented by further examinations for definitive clinical decision making. (C) 2021 - The authors. Published by IOS Press.
Název v anglickém jazyce
Correlation between palpatory assessment and pressure sensors in response to postural trunk tests
Popis výsledku anglicky
BACKGROUND: The evaluation of postural trunk muscle function is a critical component of clinical assessment in patients with musculoskeletal pain and dysfunction. Postural activation of the trunk muscles has been evaluated by various methods. This study evaluates the correlation between subjective assessment of postural trunk muscle function with an objective measurement of abdominal wall expansion. METHODS: Twenty-five healthy participants (16 women, 9 men, age 22.4 years) were assessed. The subjective assessment was performed by two experienced Dynamic Neuromuscular Stabilization (DNS) clinicians evaluating the quality of trunk stabilization using five postural stability tests through palpation and observation. Interrater reliability was determined using an intraclass correlation coefficients (ICC). Objective measurement was performed using a new device (DNS Brace) which externally measures abdominal wall pressure. Spearman rank correlations were calculated for both palpation and observation measures with DNS Brace data. RESULTS: The interrater reliability (ICC2,k) estimates demonstrated moderate reliability in palpation measures for three DNS tests: Hip flexion test, Diaphragm test, & Intra-abdominal pressure regulation test (IAPRT) (ICC = 0.645-0.707). For observation measures, good reliability was found in IAPRT (ICC = 0.835), and three tests demonstrated moderate reliability: Hip flexion test, Diaphragm test, & Breathing Stereotype (ICC = 0.577-0.695). Correlation analysis demonstrated several moderate to strong correlations between palpation and DNS brace values (Assessor 1): IAPRT, rs= 0.580, p= 0.002, Diaphragm test, rs= 0.543, p= 0.005, (Assessor 2): IAPRT, rs= 0.776, p< 0.001, Breathing Stereotype, rs= 0.625, p= 0.001, Diaphragm test, rs= 0.519, p= 0.008, Hip Flexion test, rs= 0.536, p= 0.006, and Arm Elevation test, rs= 0.460, p= 0.021. For observation, several moderate correlations were demonstrated with DNS brace values (Assessor 1): Arm Elevation test, rs= 0.472, p= 0.017, (Assessor 2) Diaphragm test, rs= 0.540, p= 0.005, IAPRT rs= 0.475, p= 0.016, Hip Flexion test, rs= 0.485, p= 0.014, and Arm Elevation, rs= 0.451, p= 0.024. CONCLUSION: Based on inter-rater reliability and DNS brace correlations with trained DNS professionals, the IAPRT, Diaphragm test, and Hip Flexion test may prove useful when assessing asymptomatic individuals. More research is needed in order to establish the utility of DNS brace and clinical testing both in asymptomatic and back pain populations. DNS tests must be supplemented by further examinations for definitive clinical decision making. (C) 2021 - The authors. Published by IOS Press.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Isokinetics and Exercise Science
ISSN
0959-3020
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
299-308
Kód UT WoS článku
000679061200008
EID výsledku v databázi Scopus
2-s2.0-85110434575