Patient specific real-time PCR in precision medicine - Validation of IG/TR based MRD assessment in lymphoid leukemia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F23%3A10455267" target="_blank" >RIV/00064203:_____/23:10455267 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/23:10455267
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2IvSWPtapo" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2IvSWPtapo</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fonc.2022.1111209" target="_blank" >10.3389/fonc.2022.1111209</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Patient specific real-time PCR in precision medicine - Validation of IG/TR based MRD assessment in lymphoid leukemia
Popis výsledku v původním jazyce
Detection of patient- and tumor-specific clonally rearranged immune receptor genes using real-time quantitative (RQ)-PCR is an accepted method in the field of precision medicine for hematologic malignancies. As individual primers are needed for each patient and leukemic clone, establishing performance specifications for the method faces unique challenges. Results for series of diagnostic assays for CLL and ALL patients demonstrate that the analytic performance of the method is not dependent on patients' disease characteristics. The calibration range is linear between 10(-1) and 10(-5) for 90% of all assays. The detection limit of the current standardized approach is between 1.8 and 4.8 cells among 100,000 leukocytes. RQ-PCR has about 90% overall agreement to flow cytometry and next generation sequencing as orthogonal methods. Accuracy and precision across different labs, and above and below the clinically applied cutoffs for minimal/measurable residual disease (MRD) demonstrate the robustness of the technique. The here reported comprehensive, IVD-guided analytical validation provides evidence that the personalized diagnostic methodology generates robust, reproducible and specific MRD data when standardized protocols for data generation and evaluation are used. Our approach may also serve as a guiding example of how to accomplish analytical validation of personalized in-house diagnostics under the European IVD Regulation.
Název v anglickém jazyce
Patient specific real-time PCR in precision medicine - Validation of IG/TR based MRD assessment in lymphoid leukemia
Popis výsledku anglicky
Detection of patient- and tumor-specific clonally rearranged immune receptor genes using real-time quantitative (RQ)-PCR is an accepted method in the field of precision medicine for hematologic malignancies. As individual primers are needed for each patient and leukemic clone, establishing performance specifications for the method faces unique challenges. Results for series of diagnostic assays for CLL and ALL patients demonstrate that the analytic performance of the method is not dependent on patients' disease characteristics. The calibration range is linear between 10(-1) and 10(-5) for 90% of all assays. The detection limit of the current standardized approach is between 1.8 and 4.8 cells among 100,000 leukocytes. RQ-PCR has about 90% overall agreement to flow cytometry and next generation sequencing as orthogonal methods. Accuracy and precision across different labs, and above and below the clinically applied cutoffs for minimal/measurable residual disease (MRD) demonstrate the robustness of the technique. The here reported comprehensive, IVD-guided analytical validation provides evidence that the personalized diagnostic methodology generates robust, reproducible and specific MRD data when standardized protocols for data generation and evaluation are used. Our approach may also serve as a guiding example of how to accomplish analytical validation of personalized in-house diagnostics under the European IVD Regulation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
<a href="/cs/project/LX22NPO5102" target="_blank" >LX22NPO5102: Národní ústav pro výzkum rakoviny</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Oncology [online]
ISSN
2234-943X
e-ISSN
2234-943X
Svazek periodika
12
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1111209
Kód UT WoS článku
000923313100001
EID výsledku v databázi Scopus
2-s2.0-85147151999