Popis výsledku v původním jazyce
Diffusion Magnetic Resonance Imaging (dMRI) is a widely-utilized method for assessment of microstructural properties in the central nervous system i.e., the brain and spinal cord (SC). In the SC, almost all previous human studies utilized Diffusion Tensor Imaging (DTI), which cannot accurately model areas where white matter (WM) pathways cross or diverge. While High Angular Diffusion Resolution Imaging (HARDI) can overcome some of these limitations, longer acquisition times critically limit its applicability to clinical human studies. In addition, previous human HARDI studies have used limited spatial resolution, with typically a few slices and voxel size ~1 × 1 × 5 mm 3 being acquired in tens of minutes. Thus, we have optimized a novel fast HARDI protocol that allows collecting dMRI data at high angular and spatial resolutions in clinically-feasible time.
Název v anglickém jazyce
Fast in vivo high-resolution diffusion MRI of the human cervical spinal cord microstructure
Popis výsledku anglicky
Diffusion Magnetic Resonance Imaging (dMRI) is a widely-utilized method for assessment of microstructural properties in the central nervous system i.e., the brain and spinal cord (SC). In the SC, almost all previous human studies utilized Diffusion Tensor Imaging (DTI), which cannot accurately model areas where white matter (WM) pathways cross or diverge. While High Angular Diffusion Resolution Imaging (HARDI) can overcome some of these limitations, longer acquisition times critically limit its applicability to clinical human studies. In addition, previous human HARDI studies have used limited spatial resolution, with typically a few slices and voxel size ~1 × 1 × 5 mm 3 being acquired in tens of minutes. Thus, we have optimized a novel fast HARDI protocol that allows collecting dMRI data at high angular and spatial resolutions in clinically-feasible time.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering
ISBN
978-981-10-9023-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
3-7
Název nakladatele
Springer
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
6. 3. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—