In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F21%3AN0000179" target="_blank" >RIV/00098892:_____/21:N0000179 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/21:73608793
Výsledek na webu
<a href="https://journals.lww.com/otology-neurotology/Abstract/2021/09000/In_Vivo_Measurements_of_Middle_Ear_Temperature.22.aspx" target="_blank" >https://journals.lww.com/otology-neurotology/Abstract/2021/09000/In_Vivo_Measurements_of_Middle_Ear_Temperature.22.aspx</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MAO.0000000000003142" target="_blank" >10.1097/MAO.0000000000003142</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery
Popis výsledku v původním jazyce
OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.
Název v anglickém jazyce
In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery
Popis výsledku anglicky
OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Otology and Neurotology
ISSN
1531-7129
e-ISSN
1537-4505
Svazek periodika
42
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
„e1037“-„e1041“
Kód UT WoS článku
000684317000010
EID výsledku v databázi Scopus
2-s2.0-85114385470