Electrophysiological findings after bilateral thoracoscopic atrial fibrillation ablation using irrigated bipolar radiofrequency energy – a pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F22%3A10157473" target="_blank" >RIV/00098892:_____/22:10157473 - isvavai.cz</a>
Výsledek na webu
<a href="https://e-coretvasa.cz/en/artkey/cor-202205-0001_electrophysiological-findings-after-bilateral-thoracoscopic-atrial-fibrillation-ablation-using-irrigated-bipola.php" target="_blank" >https://e-coretvasa.cz/en/artkey/cor-202205-0001_electrophysiological-findings-after-bilateral-thoracoscopic-atrial-fibrillation-ablation-using-irrigated-bipola.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33678/cor.2022.055" target="_blank" >10.33678/cor.2022.055</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrophysiological findings after bilateral thoracoscopic atrial fibrillation ablation using irrigated bipolar radiofrequency energy – a pilot study
Popis výsledku v původním jazyce
Background: Thoracoscopic atrial fibrillation ablation (TARAFS) using irrigated bipolar radiofrequency energy (Medtronic Cardioblate Gemini-S) should result in wide isolation of the pulmonary veins (PVs) and posterior left atrial (LA) wall (the box-lesion technique). Electrophysiological findings after this technique using this instrumentation are not known. Methods and results: 22 patients with AF recurrence after bilateral TARAFS for persistent AF had a radiofrequency catheter ablation (CA) at least three months after TARAFS. Results: Out of 22 patients, the box lesion was not completed in 15 (68.2%) patients. 12 had no endocardial signs of any prior ablation, 2 had right pulmonary PVs isolated and 1 had left PVs isolated. At the end of CA, box lesion was finished in all 15 patients and AF non-inducibility was achieved in 18 patients. Conclusion: In a considerable number of patients with AF recurrence after TARAFS box lesion is not finished and no signs of prior ablation to guide a touch-up catheter ablation are found on electroanatomical voltage map. In majority of patients, additional ablation beside box lesion is needed to achieve AF non-inducibility.
Název v anglickém jazyce
Electrophysiological findings after bilateral thoracoscopic atrial fibrillation ablation using irrigated bipolar radiofrequency energy – a pilot study
Popis výsledku anglicky
Background: Thoracoscopic atrial fibrillation ablation (TARAFS) using irrigated bipolar radiofrequency energy (Medtronic Cardioblate Gemini-S) should result in wide isolation of the pulmonary veins (PVs) and posterior left atrial (LA) wall (the box-lesion technique). Electrophysiological findings after this technique using this instrumentation are not known. Methods and results: 22 patients with AF recurrence after bilateral TARAFS for persistent AF had a radiofrequency catheter ablation (CA) at least three months after TARAFS. Results: Out of 22 patients, the box lesion was not completed in 15 (68.2%) patients. 12 had no endocardial signs of any prior ablation, 2 had right pulmonary PVs isolated and 1 had left PVs isolated. At the end of CA, box lesion was finished in all 15 patients and AF non-inducibility was achieved in 18 patients. Conclusion: In a considerable number of patients with AF recurrence after TARAFS box lesion is not finished and no signs of prior ablation to guide a touch-up catheter ablation are found on electroanatomical voltage map. In majority of patients, additional ablation beside box lesion is needed to achieve AF non-inducibility.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
1803-7712
Svazek periodika
64
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
499-503
Kód UT WoS článku
000933055200002
EID výsledku v databázi Scopus
2-s2.0-85147325239