Procedural Safety and Device Performance of the Portico™ Valve from Experienced TAVI Centers: 30-Day Outcomes in the Multicenter CONFIDENCE Registry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F22%3A10157800" target="_blank" >RIV/00098892:_____/22:10157800 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2077-0383/11/16/4839" target="_blank" >https://www.mdpi.com/2077-0383/11/16/4839</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jcm11164839" target="_blank" >10.3390/jcm11164839</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Procedural Safety and Device Performance of the Portico™ Valve from Experienced TAVI Centers: 30-Day Outcomes in the Multicenter CONFIDENCE Registry
Popis výsledku v původním jazyce
A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a Portico™ transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNav™ DS. The objective of this registry is to characterize the procedural safety and device performance of the Portico™ THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single Portico™ THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm2 and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The Portico™ THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the Portico™ THV with either the first-generation DS or FlexNav™ DS.
Název v anglickém jazyce
Procedural Safety and Device Performance of the Portico™ Valve from Experienced TAVI Centers: 30-Day Outcomes in the Multicenter CONFIDENCE Registry
Popis výsledku anglicky
A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a Portico™ transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNav™ DS. The objective of this registry is to characterize the procedural safety and device performance of the Portico™ THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single Portico™ THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm2 and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The Portico™ THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the Portico™ THV with either the first-generation DS or FlexNav™ DS.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Clinical Medicine
ISSN
2077-0383
e-ISSN
2077-0383
Svazek periodika
11
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
4839
Kód UT WoS článku
000845828700001
EID výsledku v databázi Scopus
2-s2.0-85137326554