Comparison of capabilities and limitations of endoscopes in endoscopic ear surgeries using 3D printed models
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F24%3A10158597" target="_blank" >RIV/00098892:_____/24:10158597 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/24:73624012
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0196070924000127?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0196070924000127?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.amjoto.2024.104226" target="_blank" >10.1016/j.amjoto.2024.104226</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of capabilities and limitations of endoscopes in endoscopic ear surgeries using 3D printed models
Popis výsledku v původním jazyce
Purpose: Endoscopic ear surgery has become a popular operative approach to treat middle ear diseases. Surgeons use either 0° or 30° endoscopes worldwide. The main aim of the work was to compare the properties of these two types of endoscopes. Material and methods: Since this type of evaluation is hard to perform in vivo during the actual surgery, we designed 3D printed temporal bone models with different levels of complexity. The evaluation of endoscopes was based on image analysis or visibility of anatomical structures. Results: The results show that a 30° endoscope offers a view of lateral walls from 4 mm distance, contrary to a 0° endoscope which cannot see lateral walls from this distance at all. On the other hand, visible area of the anterior wall is up to 40 % larger using 0° endoscope, compared to 30° endoscope. Angled endoscope distorts the picture and leads to the deterioration of the image. At commonly used distances above 5 mm from middle ear structures, resolution and image distortion is comparable between both endoscopes. Conclusions: Our results do not offer a definitive opinion on which endoscope is better for ear surgery. Both types of endoscopes have advantages and disadvantages, and the choice depends on the surgeon's personal preference and on the type of planned procedure.
Název v anglickém jazyce
Comparison of capabilities and limitations of endoscopes in endoscopic ear surgeries using 3D printed models
Popis výsledku anglicky
Purpose: Endoscopic ear surgery has become a popular operative approach to treat middle ear diseases. Surgeons use either 0° or 30° endoscopes worldwide. The main aim of the work was to compare the properties of these two types of endoscopes. Material and methods: Since this type of evaluation is hard to perform in vivo during the actual surgery, we designed 3D printed temporal bone models with different levels of complexity. The evaluation of endoscopes was based on image analysis or visibility of anatomical structures. Results: The results show that a 30° endoscope offers a view of lateral walls from 4 mm distance, contrary to a 0° endoscope which cannot see lateral walls from this distance at all. On the other hand, visible area of the anterior wall is up to 40 % larger using 0° endoscope, compared to 30° endoscope. Angled endoscope distorts the picture and leads to the deterioration of the image. At commonly used distances above 5 mm from middle ear structures, resolution and image distortion is comparable between both endoscopes. Conclusions: Our results do not offer a definitive opinion on which endoscope is better for ear surgery. Both types of endoscopes have advantages and disadvantages, and the choice depends on the surgeon's personal preference and on the type of planned procedure.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
<a href="/cs/project/EF19_073%2F0016713" target="_blank" >EF19_073/0016713: Zkvalitnění schémat Doktorské studentské grantové soutěže a jejich pilotní implementace</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
American Journal of Otolaryngology
ISSN
0196-0709
e-ISSN
1532-818X
Svazek periodika
45
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
104226
Kód UT WoS článku
001175621100001
EID výsledku v databázi Scopus
2-s2.0-85184063121