Respiratory induced heart rate and blood pressure variability during mechanical ventilation in critically ill and brain death patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F12%3A%230000926" target="_blank" >RIV/00159816:_____/12:#0000926 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/12:#0001005
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EMBC.2012.6346800" target="_blank" >http://dx.doi.org/10.1109/EMBC.2012.6346800</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EMBC.2012.6346800" target="_blank" >10.1109/EMBC.2012.6346800</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Respiratory induced heart rate and blood pressure variability during mechanical ventilation in critically ill and brain death patients
Popis výsledku v původním jazyce
We analysed respiratory induced heart rate and blood pressure variability in mechanically ventilated patients with different levels of sedation and central nervous system activity. Our aim was to determine whether it is possible to distinguish differentlevels of sedation or human brain activity from heart rate and blood pressure. We measured 19 critically ill and 15 brain death patients ventilated at various respiratory frequencies - 15, 12, 8 and 6 breaths per minute. Basal and deeper sedation was performed in the critically ill patients. We detected and analysed heart rate and blood pressure parameters induced by ventilation. Results: Respiratory induced heart rate variability is the unique parameter that can differentiate between brain death patients and sedated critically ill patients. Significant differences exist, especially during slow deep breathing with a mean period of 10 seconds. The limit values reflecting brain death are: baroreflex lower than 0.5 ms/mmHg and tidal volume
Název v anglickém jazyce
Respiratory induced heart rate and blood pressure variability during mechanical ventilation in critically ill and brain death patients
Popis výsledku anglicky
We analysed respiratory induced heart rate and blood pressure variability in mechanically ventilated patients with different levels of sedation and central nervous system activity. Our aim was to determine whether it is possible to distinguish differentlevels of sedation or human brain activity from heart rate and blood pressure. We measured 19 critically ill and 15 brain death patients ventilated at various respiratory frequencies - 15, 12, 8 and 6 breaths per minute. Basal and deeper sedation was performed in the critically ill patients. We detected and analysed heart rate and blood pressure parameters induced by ventilation. Results: Respiratory induced heart rate variability is the unique parameter that can differentiate between brain death patients and sedated critically ill patients. Significant differences exist, especially during slow deep breathing with a mean period of 10 seconds. The limit values reflecting brain death are: baroreflex lower than 0.5 ms/mmHg and tidal volume
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE Engineering in Medicine and Biology Society Conference Proceedings
ISBN
978-1-4577-1787-1
ISSN
1557-170X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
3821-3824
Název nakladatele
IEEE, 345 E 47TH ST, NEW YORK, NY 10017 USA
Místo vydání
—
Místo konání akce
San Diego, California USA
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000313296504012