Measurement of blood filling in lower limbs by bioimpedance method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00067629" target="_blank" >RIV/00159816:_____/17:00067629 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/17:PU136940
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of blood filling in lower limbs by bioimpedance method
Popis výsledku v původním jazyce
Background: Cardiovascular diseases are the leading causes of mortality and morbidity in modern society. The autonomic nervous systems innervate blood vessel walls and regulate contraction and wall tension. The head-up tilt test is frequently performed for evaluating sympathetic nervous system function. The filling of the lower extremities during the head-up tilt test is measured by the bioimpedance method. Increased blood volume in the area of interest increases the electrical impedance of this area. Methods: We used a mathematical fitting model to express the measured data. A B time constant of a decreased bioimpedance signal during a head-up tilt was calculated for the right leg during various time intervals of tilt duration. We optimized the duration in a study protocol based on corresponding measured data and a calculated model. A group of 22 healthy volunteers (11 men and 11 women) participated in the study protocol: the protocol included a 2-minute supine position and 5-minute head-up tilt test. Results: According to the Mann-Whitney test, there were no statistical differences in the B constant between the groups of men and women. Our results showed the optimal time duration of the head-up tilt test to be about 270 s. Conclusions: Calculating the time constant for decreased bioimpedance during a head-up tilt test might lead to a simple pre-diagnostic method for performing a non-invasive evaluation of the cardiovascular system.
Název v anglickém jazyce
Measurement of blood filling in lower limbs by bioimpedance method
Popis výsledku anglicky
Background: Cardiovascular diseases are the leading causes of mortality and morbidity in modern society. The autonomic nervous systems innervate blood vessel walls and regulate contraction and wall tension. The head-up tilt test is frequently performed for evaluating sympathetic nervous system function. The filling of the lower extremities during the head-up tilt test is measured by the bioimpedance method. Increased blood volume in the area of interest increases the electrical impedance of this area. Methods: We used a mathematical fitting model to express the measured data. A B time constant of a decreased bioimpedance signal during a head-up tilt was calculated for the right leg during various time intervals of tilt duration. We optimized the duration in a study protocol based on corresponding measured data and a calculated model. A group of 22 healthy volunteers (11 men and 11 women) participated in the study protocol: the protocol included a 2-minute supine position and 5-minute head-up tilt test. Results: According to the Mann-Whitney test, there were no statistical differences in the B constant between the groups of men and women. Our results showed the optimal time duration of the head-up tilt test to be about 270 s. Conclusions: Calculating the time constant for decreased bioimpedance during a head-up tilt test might lead to a simple pre-diagnostic method for performing a non-invasive evaluation of the cardiovascular system.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BIOMEDICAL PAPERS-OLOMOUC
ISSN
1213-8118
e-ISSN
—
Svazek periodika
161
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
"S15"-"S19"
Kód UT WoS článku
000428945000003
EID výsledku v databázi Scopus
—