Hemodynamic modelling in the calf — A pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00474796" target="_blank" >RIV/68081731:_____/16:00474796 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.22489/CinC.2016.149-433" target="_blank" >http://dx.doi.org/10.22489/CinC.2016.149-433</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22489/CinC.2016.149-433" target="_blank" >10.22489/CinC.2016.149-433</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hemodynamic modelling in the calf — A pilot study
Popis výsledku v původním jazyce
With increasing age, the cardiovascular system loses its efficiency. The goal of this work was to investigate the hemodynamic system response to a head-up tilt test in two groups of different aged people. We used a model for describing this response in the right calf based on a non-invasive, non-occlusive, bioimpedance signal measurement technique. A decrease in the bioimpedance value in the calf during the head-up tilt test is associated with the accumulation of blood in the calf, which can be expressed by a model parameter. Subjects were examined in both a head-up tilt test and a supine position. 50 healthy non-smoking volunteers were divided into two groups according to age. The impedance signal during the tilt test for each subject was fitted by a model exponential function: Z0 model EF(t) =A exp(-t/B)+C, where Z0 model EF(t) is the calculated model of electrical impedance in the calf by an exponential function, A is the amplitude of impedance change, B is the time constant of the impedance decrease, C is the value of the steady state after the tilt test and t denotes time. A lower time constant B shows a faster filling of the vascular system in the investigated part. The Mann-Whitney test (p-value<,0.005) revealed that the time constant B for the older group was significantly lower than for the young group (145.24+/- 80.28 vs. 239.23+/-136.59 sec.). A lower time constant value means a faster response to blood filling in the lower limbs and directly reflects decreased vessel elasticity. This time constant was lower in the older group. The results show increased vessel stiffness in old age and could lead to a non-invasive evaluating the cardiovascular system state.
Název v anglickém jazyce
Hemodynamic modelling in the calf — A pilot study
Popis výsledku anglicky
With increasing age, the cardiovascular system loses its efficiency. The goal of this work was to investigate the hemodynamic system response to a head-up tilt test in two groups of different aged people. We used a model for describing this response in the right calf based on a non-invasive, non-occlusive, bioimpedance signal measurement technique. A decrease in the bioimpedance value in the calf during the head-up tilt test is associated with the accumulation of blood in the calf, which can be expressed by a model parameter. Subjects were examined in both a head-up tilt test and a supine position. 50 healthy non-smoking volunteers were divided into two groups according to age. The impedance signal during the tilt test for each subject was fitted by a model exponential function: Z0 model EF(t) =A exp(-t/B)+C, where Z0 model EF(t) is the calculated model of electrical impedance in the calf by an exponential function, A is the amplitude of impedance change, B is the time constant of the impedance decrease, C is the value of the steady state after the tilt test and t denotes time. A lower time constant B shows a faster filling of the vascular system in the investigated part. The Mann-Whitney test (p-value<,0.005) revealed that the time constant B for the older group was significantly lower than for the young group (145.24+/- 80.28 vs. 239.23+/-136.59 sec.). A lower time constant value means a faster response to blood filling in the lower limbs and directly reflects decreased vessel elasticity. This time constant was lower in the older group. The results show increased vessel stiffness in old age and could lead to a non-invasive evaluating the cardiovascular system state.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology (CinC) 2016
ISBN
978-1-5090-0896-4
ISSN
2325-8861
e-ISSN
—
Počet stran výsledku
4
Strana od-do
525-528
Název nakladatele
Computing in Cardiology
Místo vydání
Vencouver
Místo konání akce
Vencouver
Datum konání akce
11. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000405710400132