Efficient Implementation of Stockwell Transform for Real-time Embedded Processing of Physiologic Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00068431" target="_blank" >RIV/00159816:_____/17:00068431 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/17:PU126193
Výsledek na webu
<a href="https://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8026122" target="_blank" >https://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8026122</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EMBC.2017.8037389" target="_blank" >10.1109/EMBC.2017.8037389</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Efficient Implementation of Stockwell Transform for Real-time Embedded Processing of Physiologic Signals
Popis výsledku v původním jazyce
Physiologic monitoring enables scientists and physicians to study both normal and pathologic signals of the body. While wearable technologies are available today, many of these technologies are limited to data collection only. Embedded processors have minimal computational capabilities. We propose an efficient implementation of the Stockwell Transform which can enable real-time time-frequency analysis of biological signals in a microcontroller. The method is built upon the fact that the Stockwell Transform can be implemented as a compact filter bank with pre-computed filter taps. Additionally, due to the long tails of the gaussian windowing function, low amplitude filter taps can be removed. The method was implemented on a TI MSP430 processor. Simulated ECG data was fed into the processor to demonstrate performance and evaluate computational efficiency.
Název v anglickém jazyce
Efficient Implementation of Stockwell Transform for Real-time Embedded Processing of Physiologic Signals
Popis výsledku anglicky
Physiologic monitoring enables scientists and physicians to study both normal and pathologic signals of the body. While wearable technologies are available today, many of these technologies are limited to data collection only. Embedded processors have minimal computational capabilities. We propose an efficient implementation of the Stockwell Transform which can enable real-time time-frequency analysis of biological signals in a microcontroller. The method is built upon the fact that the Stockwell Transform can be implemented as a compact filter bank with pre-computed filter taps. Additionally, due to the long tails of the gaussian windowing function, low amplitude filter taps can be removed. The method was implemented on a TI MSP430 processor. Simulated ECG data was fed into the processor to demonstrate performance and evaluate computational efficiency.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)
ISBN
978-1-5090-2809-2
ISSN
1094-687X
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
2598-2601
Název nakladatele
IEEE
Místo vydání
NEW YORK
Místo konání akce
SOUTH KOREA
Datum konání akce
11. 7. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000427085303011