DEFORMATION RESPONSE OF POLYDIMETHYLSILOXANE SUBSTRATES SUBJECTED TO UNIAXIAL QUASI-STATIC LOADING
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F19%3A00074109" target="_blank" >RIV/00159816:_____/19:00074109 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378297:_____/19:00505063
Výsledek na webu
<a href="http://dx.doi.org/10.14311/APP.2019.25.0079" target="_blank" >http://dx.doi.org/10.14311/APP.2019.25.0079</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2019.25.0079" target="_blank" >10.14311/APP.2019.25.0079</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DEFORMATION RESPONSE OF POLYDIMETHYLSILOXANE SUBSTRATES SUBJECTED TO UNIAXIAL QUASI-STATIC LOADING
Popis výsledku v původním jazyce
To investigate cellular response of cardiomyocytes to substrate mechanics, biocompatible material with stiffness in physiological range is needed. PDMS based material is used for construction of microfluidic organ on chip devices for cell culture due to ease of device preparation, bonding, and possibility of surface functionalization. However it has stiffness orders of magnitude out of physiological range. Therefore, we adapted recently available protocol aiming to prepare substrates which offer stiffness in physiological range 5 - 100 kPa using various mixtures of Sylgard. An in-house developed loading device with single micron position tracking accuracy and sub-micron position sensitivity was adapted for this experimental campaign. All batches of the samples were subjected to uniaxial loading. During quasi-static experiment the samples were compressed to minimally 40 % deformation. The results are represented in the form of stress-strain curves calculated from the acquired force and displacement data and elastic moduli are estimated.
Název v anglickém jazyce
DEFORMATION RESPONSE OF POLYDIMETHYLSILOXANE SUBSTRATES SUBJECTED TO UNIAXIAL QUASI-STATIC LOADING
Popis výsledku anglicky
To investigate cellular response of cardiomyocytes to substrate mechanics, biocompatible material with stiffness in physiological range is needed. PDMS based material is used for construction of microfluidic organ on chip devices for cell culture due to ease of device preparation, bonding, and possibility of surface functionalization. However it has stiffness orders of magnitude out of physiological range. Therefore, we adapted recently available protocol aiming to prepare substrates which offer stiffness in physiological range 5 - 100 kPa using various mixtures of Sylgard. An in-house developed loading device with single micron position tracking accuracy and sub-micron position sensitivity was adapted for this experimental campaign. All batches of the samples were subjected to uniaxial loading. During quasi-static experiment the samples were compressed to minimally 40 % deformation. The results are represented in the form of stress-strain curves calculated from the acquired force and displacement data and elastic moduli are estimated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17TH YOUTH SYMPOSIUM ON EXPERIMENTAL SOLID MECHANICS (YSESM 2019)
ISBN
978-80-01-06670-6
ISSN
2336-5382
e-ISSN
—
Počet stran výsledku
4
Strana od-do
79-82
Název nakladatele
CZECH TECHNICAL UNIV PRAGUE
Místo vydání
PRAGUE 6
Místo konání akce
Telc
Datum konání akce
6. 6. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000546061600016