The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F20%3A00072994" target="_blank" >RIV/00159816:_____/20:00072994 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/europace/article-abstract/22/5/777/5704431?redirectedFrom=fulltext" target="_blank" >https://academic.oup.com/europace/article-abstract/22/5/777/5704431?redirectedFrom=fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euz346" target="_blank" >10.1093/europace/euz346</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients
Popis výsledku v původním jazyce
Aims The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. Methods and results Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n=27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.011 The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. Conclusions Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.
Název v anglickém jazyce
The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients
Popis výsledku anglicky
Aims The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. Methods and results Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n=27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.011 The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. Conclusions Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
777-786
Kód UT WoS článku
000553184400016
EID výsledku v databázi Scopus
—